Service Mode
Test "t4" --- Inlet Valve & Pressure Sensor Check
• Press start to initiate test.
• Each time start is pressed a different valve is energized and a
different corresponding letter is displayed.
A : Cold valve is energized.
b : Hot valve is energized.
C : Jet spray valve is energized.
d : Bleach valve is energized.
E : Softener valve is energized.
• Pump will activate when water frequency is 21.0 KHz.
• Water level frequency will be displayed.
Test "t5" --- Heater / Thermister Test
• Press start to initiate test.
• Tub will begin to fill with water.
• When water reached the 25.8 KHZ level, heater will be energized
for 5 minutes.
• Water temperature will be displayed.
• After 5 minutes, pump is energized.