The charger can only be used for rechargeable lead/acid batteries. • Do not recharge non-rechargeable batteries. • The charging wires can only be changed to other keepower wires. • If the supply cord is damaged, it must be replaced by authorised shop. •...
Small, Medium, Large and XL-Con Flash light button Battery indicator Full Flash light Medium Discharged battery Deep Discharged Error indicator Charging mode: Small 1Aor4A/12V Bike charging Cold charging Normal charging Charging mode: Supply mode Medium 8A/12V Cold charging Large15A/12V Normal charging...
Page 5
Incase of overload, the Warning LED flashes. If heavy overload, the charger switches off to protect it self (only Keepower Medium, Keepower Large and Keepower XL-con). A battery has to be connected for activation of “Supply mode”. Please note that spark protection is not active when in supply mode.
Small, Medium, Large and XL-Con Procedure how to charge or detect a battery. For reliable reading, the battery should be at room temperature (20 ºC), and it must have been resting for at least 4 hours (no charging has taken place either in the vehicle or using the Inelco Intelligent Battery Care charger).
Page 7
Small, Medium, Large and XL-Con Keepower chargers This user guide can be used for 4 variants of the Keepower chargers. The first part of the user guide is a general part and the last part is special for the XL-con. Small Medium Large XL-con How to install the charger The charger can be installed in 4 different positions.
Page 8
Small, Medium, Large and XL-Con Testing Soft charge Desulphation Bulk charge Absorption After charge Testing Maintenance Maintenance The intelligent charging curve Soft charge (Indication: Discharged LED flashing): The “soft charge” phase is used when the battery is deep dis- charged. The battery is charged until it is ready to receive normal charging (12.0V) and then the normal charging is started.
Page 9
Small, Medium, Large and XL-Con After charging (Indication: Full LED flashing): The “after charging” phase is the phase where the battery under a constant voltage is charged to app. 100% of the full capacity. The voltage is raised 0.4V compared to the Bulk charging phase.
Small, Medium, Large and XL-Con Error indication Warning flashing: • Clamps not connected to battery. • Mains cable not plugged in or mains switch not switched on. • Supply: overload, i.e. the voltage is dropping due to loading with more than the nominal current (8/15/30A).
Page 11
The flash light can be replaced. Please order sparepart no. 4500 4105 (see picture 2). Keepower XL version Temperature sensor The Keepower XL version has a temperature sensor in the battery clamp. This sensor is used to adjust the charging parameter while charging the bat- tery. USB connection Can be used as a connection to other devices(mobilphones, Ipod) that need to be charged.
Small, Medium, Large and XL-Con Technical data CLASSIC MICRO SMALL MEDIUM LARGE XL-con XL-pro Nominal 12/24V 12/24V battery voltage Charge 0.8A 0.8A 30A/15A 30A/15A Current Battery size 1.2Ah to 32 Ah 1.2Ah to 32Ah 3Ah to 80Ah 20Ah to 160Ah 40Ah to 300Ah 90Ah to 600Ah 3Ah to 600Ah Max.