12.2.4
Connect the Cable to the Indoor Unit
1
The inside and outside connecting cable can
be connected without removing the front grille.
2
Connection cable between indoor unit and
outdoor unit shall be approved
polychloroprene sheathed 4 x 1.5 mm
cord, type designation 245 IEC 57 or heavier
cord.
3
Bind all the indoor and outdoor connecting
cable with tape and route the connecting
cable via the escapement.
4
Remove the tapes and connect the
connecting cable between indoor unit and
outdoor unit according to the diagram below.
5
Secure the connecting cable onto the control board with the holder (clamper).
Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor's
o
respectively.
Earth wire shall be Yellow/Green (Y/G) in colour and longer than other AC wires for safety reason.