Troubleshooting Check Table - Mitsubishi Electric MUZ-GF60VE Service Manual

Split-type
Hide thumbs Also See for MUZ-GF60VE:
Table of Contents

Advertisement

11-3. TROUBLESHOOTING CHECK TABLE

No.
Symptom
LED indication
Outdoor unit
1-time fl ash every
does not op-
2.5 seconds
1
erate.
2
3
6-time fl ash
2.5 seconds OFF
4
11-time fl ash
5
2.5 seconds OFF
16-time fl ash
2.5 seconds OFF
6
'Outdoor unit
2-time fl ash
stops and
2.5 seconds OFF
7
restarts 3
minutes later'
is repeated.
3-time fl ash
2.5 seconds OFF
8
4-time fl ash
2.5 seconds OFF
9
5-time fl ash
2.5 seconds OFF
10
8-time fl ash
2.5 seconds OFF
11
10-time fl ash
2.5 seconds OFF
12
12-time fl ash
13
2.5 seconds OFF
13-time fl ash
2.5 seconds OFF
14
Outdoor unit
1-time fl ash
15
operates.
2.5 seconds OFF
3-time fl ash
2.5 seconds OFF
16
4-time fl ash
2.5 seconds OFF
17
7-time fl ash
2.5 seconds OFF
18
OBH635
Abnormal point/
Condition
Outdoor power sys-
Overcurrent protection cut-out operates 3 consecutive times
tem
within 1 minute after the compressor gets started.
Outdoor thermistors Discharge temperature thermistor, fi n temperature thermistor,
defrost thermistor, P.C. board temperature thermistor, outdoor
heat exchanger temperature thermistor or ambient tempera-
ture thermistor shorts or opens during compressor running.
Outdoor control sys-
Memory data cannot be read.
tem
(The upper lamp of OPERATION INDICATOR lamp of the in-
door unit lights up or fl ashes 7-time.)
Serial communica-
The communication fails between the indoor and outdoor unit
tion
for 3 minutes.
Stop valve/
Closed valve is detected.
Closed valve
4-way valve/
The 4-way valve does not work properly.
Pipe temperature
The indoor coil thermistor detects an abnormal temperature.
Overcurrent protec-
Large current fl ows into IGBT module (IC700).
tion
Discharge tempera-
Temperature of discharge temperature thermistor exceeds
ture overheat protec-
116°C, compressor stops. Compressor can restart if discharge
tion
temperature thermistor reads 100°C or less 3 minutes later.
Fin temperature
Temperature of fi n temperature thermistor on the heat sink
/P.C. board tem-
exceeds 75 ~ 80°C or temperature of P.C. board temperature
perature thermistor
thermistor on the inverter P.C.board exceeds 70 ~ 75°C.
overheat protection
High pressure pro-
Indoor coil thermistor exceeds 70°C in HEAT mode. Defrost
tection
thermistor exceeds 70°C in COOL mode.
Compressor syn-
Compressor current is abnormal.
chronous abnormal-
ity
Outdoor fan motor
Outdoor fan has stopped 3 times in a row within 30 seconds
after outdoor fan start-up.
Compressor current Compressor current cannot be detected normally.
Bus-bar voltage
Bus-bar voltage cannot be detected normally.
(DC)
Frequency drop by
Current from power outlet is nearing breaker capacity.
current protection
Frequency drop by
Temperature of indoor coil thermistor exceeds 55°C in HEAT
high pressure pro-
mode, compressor frequency lowers.
tection
Frequency drop by
Indoor coil thermistor reads 8°C or less in COOL mode, com-
defrosting in COOL
pressor frequency lowers.
mode
Frequency drop by
Temperature of discharge temperature thermistor exceeds
discharge tempera-
111°C, compressor frequency lowers.
ture protection
Low discharge tem-
Temperature of discharge temperature thermistor has been
perature protection
50°C or less for 20 minutes.
Condition
26
Remedy
Reconnect connector of compres-
sor.
Refer to 11-5.
"How to check in-
verter/compressor".
Check stop valve.
Refer to 11-5.
"Check of outdoor
thermistors".
Replace inverter P.C. board.
Check connection between the
inverter P.C. board and relay P.C.
board.
Refer to 11-5.
"How to check mis-
wiring and serial signal error.
Check stop valve.
Refer to 11-5.
"Check of R.V.
coil".
Replace inverter P.C. board.
Reconnect connector of compres-
sor.
Refer to 11-5.
"How to check in-
verter/compressor".
Check stop valve.
Check refrigerant circuit and refrig-
erant amount.
Refer to 11-5.
"Check of LEV".
Check around outdoor unit.
Check outdoor unit air passage.
Refer to 11-5.
"Check of outdoor
fan motor".
Check refrigerant circuit and refrig-
erant amount.
Check stop valve.
Reconnect connector of compres-
sor.
Refer to 11-5.
"How to check in-
verter/compressor".
Refer to 11-5.
"Check of outdoor
fan motor.
Refer to 11-5.
"Check of inverter
P.C. board.
Refer to 11-5.
"How to check in-
verter/compressor".
It occurs with following case.
Instantaneous power voltage drop.
(Short time power failure)
Refer to 11-5.
"Check of power
supply".
Refer to 11-5.
"How to check in-
verter/compressor".
The unit is normal, but check the
following.
Check if indoor fi lters are clogged.
Check if refrigerant is short.
Check if indoor/outdoor unit air cir-
culation is short cycled.
Check refrigerant circuit and refrig-
erant amount.
Refer to 11-5.
"Check of LEV".
Refer to 11-5.
"Check of outdoor
thermistors".
Refer to 11-5.
"Check of LEV".
Check refrigerant circuit and refrig-
erant amount.