GARDTEC 800 User Instructions

GARDTEC 800 User Instructions

800 series
Hide thumbs Also See for 800:

Advertisement

G G
A A
R R
D D
T T
E E
C C
G G
A A
R R
D D
T T
E E
C C
8 8
0 0
0 0
S S
e e
r r
i i
e e
s s
8 8
0 0
0 0
S S
e e
r r
i i
e e
s s
User Instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 800 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GARDTEC 800

  • Page 1 User Instructions...
  • Page 2: Table Of Contents

    User Manual GARDTEC 800 Series Contents User Information ............Introduction ..............User Code Types ............3 - 4 Setting The System ............Unsetting The System ..........Part Setting The System ..........Area Setting ..............Removing Zones............Testing The System ............
  • Page 3: User Information

    User Manual GARDTEC 800 Series User Information Customer Name:- Customer Address:- Tick Tick Tick Control Panel Model No of Keypads Keypad 1 Location Type Keypad 2 Location Type Keypad 4 Location Type Keypad 5 Location (872) Type Keypad 6 Location (872)
  • Page 4: Introduction

    GARDTEC 800 Series Introduction The Gardtec 800 Series of control panels consists of 3 models, the Gardtec 800 , the Gardtec 816 and the Gardtec 872 . Two types of display are available for the system keypads, a) LCD offering a 32 character display with zone descriptors and user names or, b) twin seven segment LED display.
  • Page 5 User Manual GARDTEC 800 Series 4 = Master Allows Setting, Unsetting, Zone Remove (if programmed by (User 1 always Master) engineer), Test System, View Log, Chime On/Off, User Codes, Set Time/Date, Reset After Alarm (if programmed by engineer), Unsetting. 5 = Cleaner...
  • Page 6 Group Code Levels (affecting group or groups of areas) Group Master Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Viewing the Log, Chime On/Off, Program User Codes, Set Time/Date, Unsetting. Will also allow setting/unsetting of individual areas for greater system control Group Main Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Unsetting.
  • Page 7: Setting The System

    User Manual GARDTEC 800 Series Setting The System With the display showing:- 01 JAN 18 : 58 : 01 Enter your User code. (Followed by YES if a Master or Main type code EXIT ! 1 has been used). The display will show:- All Zones ON and a continuous exit tone will sound.
  • Page 8: Unsetting The System

    EXIT ! 1 display will show for example:- Part 1 (1 2 3 may not show on Gardtec 800 & 816) Note: (872 Only) If a Global code (Master or Main) has been used all areas that are being set will be Part 1 set.
  • Page 9 User Manual GARDTEC 800 Series The exit tone may or may not be heard dependant on the system settings. Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (depending on system settings).
  • Page 10: Area Setting

    User Manual GARDTEC 800 Series Area Setting (using Master or global Main codes) Areas will need to have been set up by the installation company. With the display showing:- 01 JAN 18 : 58 : 01 Enter a Master or global Main code, the display will show for example:- Do you want to .
  • Page 11: Removing Zones

    User Manual GARDTEC 800 Series Removing Zones (Master & Main codes only) If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. It should be noted that if an Area Main code is being used, only zones associated with that area may be removed.
  • Page 12: Testing The System

    TEST the System ? Test ALL Areas ? Press YES, the display will show:- (This step not applicable on 800 & 872) Press YES to test the full system NO until the area you wish to test is shown 1=Status 4 = Strobe...
  • Page 13: Viewing The Event Log

    User Manual GARDTEC 800 Series Whilst in Test mode any zones violated will sound the internal sounder (if it has not been silenced) and show on the display. When you have finished testing the system press 0 twice, the display will show:-...
  • Page 14: Changing The Chime Status

    User Manual GARDTEC 800 Series This is the most recent event in the log. Whilst viewing the Log, Pressing NO will move back to the previous event. Pressing YES will move forward to the next event. Pressing 7 will take you to back to the last event of the previous day.
  • Page 15 User Manual GARDTEC 800 Series Press YES the display will show for example:- Chime is Off ok ? Or:- Chime is On ok ? Press NO to change the status of the Chime, Do you want to . . then press YES, the display will show:-...
  • Page 16: Programming User Codes

    Press YES, the display will show:- (1- 99) Then YES Enter the user number (1 to 99 for 872 or 1 to 15 for 800/816) that you wish to program Now Enter Code . . - - - - - - Then YES...
  • Page 17 User Manual GARDTEC 800 Series Enter the code you require, (codes may be 4, 5 or 6 digits) followed by YES. (Entering 000000 will delete an existing code) Note: If the code already exists an error will be shown, choose another code and return to step 6...
  • Page 18 User Manual GARDTEC 800 Series Referring to the character map enter the required character (pressing the 3 key will display 'G', pressing it again will show 'H' and again will show 'I '), once the correct character is displayed press YES and the display will move on to the next position.
  • Page 19: Programming Time & Date

    User Manual GARDTEC 800 Series Programming Time & Date With the display showing:- 01 JAN 18 : 58 : 01 Enter a Master Code, the display will show:- Do you want to . . SET the System ? (User Names on 816 & 872 Only).
  • Page 20: User Initiating Remote Access

    User Manual GARDTEC 800 Series User Initiating Remote Access (Optional) Access Remote allows your installation company to examine your system and re- program system settings as you need the changes without the need for an engineer to visit your premises.
  • Page 21: Resetting After An Alarm

    User Manual GARDTEC 800 Series Resetting After an Alarm Fault and Alarm Displays Your installation company will have programmed the reset modes for your system so that it complies to your insurance company and legislation requirements. Your installation company will have informed you as to the type of reset that your system is set for.
  • Page 22 User Manual GARDTEC 800 Series Press the YES key to view the next event and carry Zone 005 TAMPER on to view any others (if present). When viewing the 01 JAN 18 : 58 : 01 <- last event the display will show, for example.
  • Page 23 To reset the system with an Anti-Code, contact the central station or engineer (as instructed by the installation company) and quote the number given by the display. The central station or engineer will give a return Anti-Code, (this may contain the YES & NO keys) for example 5, YES, 2, 4.
  • Page 24: Setting Engineer Authorisation

    User Manual GARDTEC 800 Series Setting Engineer Authorisation A User Code may be required to authorise an engineer to gain access to the system in the event of service or maintenance schedules. The level of User Code required to authorise the engineer to access the system is set within the User Menu that is accessed via a Master Level Code.
  • Page 25 User Manual GARDTEC 800 Series Do you want to . . Enter a Master User code. The display will show:- SET the System ? Press NO until the display shows:- Do you want to . . Authorise Engnr ? Engnr Authorisor Press YES.
  • Page 26: Mains Failure

    User Manual GARDTEC 800 Series Mains Failure Enter Code In the event of a Mains Power Failure the display will show:- ! ! ! ! Check ! ! ! ! At this point the system will revert to battery back-up. The battery will only have a limited time that it can sustain the system for.
  • Page 27: Re-Setting The Display After A Mains Fail

    User Manual GARDTEC 800 Series Exit the premises via the authorised exit route. Once the premises are secure listen (from outside the protected area) and wait until the exit tone finishes before leaving. Re-setting the display after a Mains Fail...
  • Page 28: Setting The System With Line Fault

    User Manual GARDTEC 800 Series Setting the system with Line Fault With the display showing:- Enter Code ! ! ! ! Check ! ! ! ! Enter your User code. Phone Line FAULT The display will then show:- Can’t Set ! Check (Followed by YES if a Master or Main type code has been used).
  • Page 29: System G-Tag

    User Manual GARDTEC 800 Series System G-Tag G-Tag Readers are available in three variants, with the reader built into the display area of an LCD RKP, as an Internal Stand alone Reader or as an External Stand alone Reader. When using G-Tag the system may be Set / Unset by presenting a valid Tag to one of the Readers.
  • Page 30: Advanced Code Programming (Control Codes)

    User Manual GARDTEC 800 Series Advanced Code Programming (Control Codes) Codes may be programmed to control Outputs and Unset the system. The Outputs that may be controlled will have been pre-programmed by your installation company and may not be changed by the user. A Master user however does have the ability to allocate the codes (not User No.1) to these Group Outputs...
  • Page 31 User Manual GARDTEC 800 Series Press NO until the Grp you wish to control is displayed. (For example Grp1). Then Press YES. Note: If a Code level other than Control has been chosen the selected Output Group will be activated each time the code is used. The use of the code will be as normal for that level of code.
  • Page 32 User Manual GARDTEC 800 Series If you wish to accept the User Name shown press User 02 Name YES and jump to step 17 = User 02 If you wish to change the User Name shown press User 1 Name NO, the display will show:- >...
  • Page 33: Advanced Setting & Unsetting Using Group Area Codes

    User Manual GARDTEC 800 Series Advanced Setting and Unsetting Using Group Area Codes There are three levels of Group Area Codes. Group Master Allows Setting, Part Setting, Area Setting, Zone Remove, System Test, Viewing the Log, Chime On/Off, Program User Codes, Set Time/Date, Unsetting.
  • Page 34: Programming Group Area User Codes

    GARDTEC 800 Series User Manual Programming Group Area User Codes With the display showing:- 01 JAN 18 : 58 : 01 Do you want to . . Enter a Master Code, the display may show:- SET the System ? Do you want to . .
  • Page 35 User Manual GARDTEC 800 Series If you wish to accept the User Name shown press User 02 Name = User 02 YES and jump to step 15. If you wish to change the User Name shown press User 1 Name >...
  • Page 36 User Manual GARDTEC 800 Series As you press YES for the ninth character (or if you have jumped from step 10) the display will Do you want to . . change to:- Prog. USER CODES ? If you wish to program other User Codes return to step 4.
  • Page 37: Setting Using Group Master & Group Main Codes

    User Manual GARDTEC 800 Series Setting Using Group Master & Group Main Codes Group Master & Group Main codes follow global Master & Main codes with respect to the level functionality. The difference lies in the ability to have individual control of the Areas that been allocated to the code.
  • Page 38: Unsetting Using Group Area Code

    User Manual GARDTEC 800 Series Unsetting Using Group Area Code Follow the instructions as for normal Unsetting. When you are using a Group Area Code only the Area(s) allocated to that code will be Unset. Unsetting Using Group Master & Group Main Codes With the display showing:- (Areas 1 &...
  • Page 39: Adding Areas

    User Manual GARDTEC 800 Series Adding Areas to a System with Area(s) already set - Group Master & Group Main Codes If your system already has an Area or Areas already Set you may add more Area(s) as required. With the display showing for example:- (Area 1 is already Set).
  • Page 40: Display Blanking

    User Manual GARDTEC 800 Series Display Blanking Dependant on the level of your system and the legislation that it is required to comply with your installation company may have initialised Display Blanking. When this is used the Status of the system will only be indicated on the display for ten seconds after it has been Set and for ten seconds after it has been Unset.
  • Page 41: Keypad Alert - If Fitted

    User Manual GARDTEC 800 Series Keypad Alert - If Fitted If programmed by your installation company, the two PA keys (if programmed by the engineer), when pressed together will act as alert keys. The exact function will depend on what they have been programmed for. But for example, if they are pro- grammed as panic, pressing them will activate the alarm when the system is set or unset.
  • Page 42: System Attributes

    User Manual GARDTEC 800 Series System Attributes Zone No. Zone Type Descriptor(816/872) Areas(872) Part Info Example Front Door 1&2 A1 Pt2 Page...
  • Page 43 User Manual GARDTEC 800 Series Zone No. Zone Type Descriptor(816/872) Areas(872) Part Info Page...
  • Page 44: Service Record

    User Manual GARDTEC 800 Series Zone No. Zone Type Descriptor(816/872) Areas(872) Part Info Service Record Date Comments Signature Alarm Reset Type:- Tamper Reset Type:- Service Company:- Tel:- Fax:- Page...
  • Page 45: User Chart

    User Manual GARDTEC 800 Series User Chart Please use this chart to indicate what user names have been programmed onto your system and those that are in use. In Use Name In Use Name User 1 User 25 User 2...
  • Page 46: Ace Instructions

    GARDTEC 800 Series ACE User Instructions ACE (Advanced Control Equipment) allows control of your Gardtec 800 Series system via Infrared Remote control. Ace is available built in to a range of keypads or as a stand alone unit, control is via neat remote keyfob(s).
  • Page 47: Programming Ace Keyfobs Onto Your System

    User Manual GARDTEC 800 Series Programming ACE Keyfobs onto your System Each keyfob will occupy a User number. The number of keyfobs that may be used is limited by the maximum number of user codes available on the system up to a maximum of fourteen.
  • Page 48 RISCO Group UK Ltd Commerce House, Whitbrook Way Stakehill Distribution Park, Middleton. Manchester. M24 2SS United Kingdom Internet: www.riscogroup.com e-mail: sales@riscogroup.co.uk RISCO Group UK Ltd reserve the right to amend the software and features without prior notice. PR5893 Rev 1.0 5IN800PDUM...