1 Safety
1.3.12 Risk of death from escaping flue
gas
If you operate the product with an empty con-
densate trap, flue gas may escape into the
room air.
▶ In order to operate the product, ensure that
the condensate trap is always full.
1.3.13 Risk of material damage caused by
using an unsuitable tool
▶ Use the correct tool to tighten or loosen
screw connections.
1.3.14 Risk of material damage caused by
frost
▶ Do not install the product in rooms prone
to frost.
1.3.15 Risk of corrosion damage due to
unsuitable combustion and room
air
Sprays, solvents, chlorinated cleaning
agents, paint, adhesives, ammonia com-
pounds, dust or similar substances may lead
to corrosion on the product and in the air/flue
pipe.
▶ Ensure that the supply of combustion air is
always free of fluorine, chlorine, sulphur,
dust, etc.
▶ Ensure that no chemical substances are
stored at the installation site.
▶ Ensure that the combustion air is not
routed through chimneys which have
previously been used with floor-standing
oil-fired boilers, or with other boilers,
which could cause soot to build up in the
chimney.
▶ If you are installing the product in
hairdressing salons, painter's or joiner's
workshops, cleaning businesses or similar
locations, choose a separate installation
room in which a combustion air supply is
ensured that is technically free of chemical
substances.
6
1.4

Related documents

Installation and maintenance of the boiler
must only be performed by a competent per-
son with valid accreditation from the Health
and Safety Executive in accordance with the
"Gas Safety (Installation and Use) Regula-
tions 1998" (hereinafter abbreviated to "com-
petent person" or "heating specialist com-
pany"). The existing regulations, rules and
guidelines must be observed when doing so.
Any special requirements of Local Author-
ities, gas undertakings or insurers must be
complied with. The competent person is also
responsible for inspection, maintenance and
repairs to the boiler, and for checking gas
volume setting and flue gas analysis.
Installers shall carryout a full site risk as-
sessment and put into place all necessary
steps and procedures to comply with Health
and safety at work act and ensure safety of
themselves and others with regard to manual
handling and working at height requirements.
During the appliance installation (and any
subsequent work, such as, the replacement
of major parts ) it will be necessary to em-
ploy caution. All installers and operatives in-
volved from unloading the appliance until it is
fully mounted on the wall in its final installed
location must exercise full duty of care for
themselves and others with regard to safety.
When lifting and handling this appliance, op-
eratives should employ assistance. In certain
situations it may be necessary to use mech-
anical handling aids. Take care to avoid trip
hazards, slippery or wet surfaces.
Employers and installers should refer
to the HSE web site for full advice and
manual handling assessment charts
(MAC) tool.
In addition where no specific instructions are
given then reference shall be made, but not
restricted to, all applicable and relevant Brit-
ish Standards and codes of practice such as
the following:
– Gas Safety (Installation and Use) regula-
tions.
– All current Building Regulations for Eng-
land, Northern Ireland and Wales, (as
amended). This includes Approved Codes
of Practice and approved documents and
Installation and maintenance instructions ecoTEC pro 0020209589_01