Download Print this page

Raynor Smart Control Panel 880RGD Quick Manual

For use with security+ 2.0 garage door openers

Advertisement

Quick Links

A
Yellow LEARN Button
Safety Reversing Sensors
A
FEATURE OVERVIEW
For use with Security+ 2.0
Garage Door Openers. All Security+ 2.0
TM
or on as desired. Refer to the Feature Settings section.
SCREEN
The screen will display the time and temperature until the menu
button is pressed, and then it will display the menu options. If
there is a problem with the garage door opener the screen will
display the Diagnostic Code.
LIGHT BUTTON
Press the LIGHT button to turn the garage door opener lights on or
off. When the lights are turned on they will stay on until the LIGHT
button is pressed again, or until the garage door opener is
activated. Once the garage door opener is activated the lights will
turn off after the specified period of time (the factory setting is
4-1/2 minutes). The LIGHT button will not control the lights when
the door is in motion. The duration of the light timing can be
adjusted by accessing the menu using the navigation buttons.
Smart Control Panel
®
Garage Door Openers have a yellow Learn button and two yellow antennas. The features are adjustable and may be turned off
TM
MOTION SENSOR
The motion sensor will automatically turn on the garage door
opener lights when motion is detected. The lights will come on for
the set period of time, then shut off. The factory setting is on and
set at 4-1/2 minutes.
LOCK
The LOCK feature is designed to prevent activation of the garage
door opener from remote controls while still allowing activation
from the door control and keyless entry. This feature is useful for
added peace of mind when the home is empty (i.e. vacation).
TIMER-TO-CLOSE (TTC)
DO NOT enable TTC if operating a one-piece door. TTC is to be
used ONLY with sectional doors. Factory default is set to off. TTC
can be set to automatically close your garage door from the fully
open position after a specified period of time (1, 5, 10 minute
1
SMART CONTROL PANEL
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is NOT connected BEFORE installing door
control.
• Connect ONLY to 12 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
intervals or a custom setting up to 99 minutes). The garage door
opener will beep and the lights will flash before closing the door.
The screen on the door control can display the status of the TTC.
TTC WILL NOT work if the garage door opener is operating by
battery power or if the safety reversing sensors are misaligned.
This feature is NOT intended to be the primary method of closing
the door. A keyless entry should be installed in the event of an
accidental lock out when using this feature.
MAINTENANCE ALERT SYSTEM (MAS)
This feature assists the homeowner in ensuring the garage door
opener system stays in good working condition. A maintenance
alert message will display on the screen indicating the garage door
opener may be in need of maintenance.
The MAS feature MUST be activated at time of installation. The
factory setting is off.
®
Model 880RGD

Advertisement

loading

Summary of Contents for Raynor Smart Control Panel 880RGD

  • Page 1 ® SMART CONTROL PANEL Model 880RGD To prevent possible SERIOUS INJURY or DEATH from electrocution: • Be sure power is NOT connected BEFORE installing door Yellow LEARN Button control. • Connect ONLY to 12 VOLT low voltage wires. To prevent possible SERIOUS INJURY or DEATH from a closing garage door: •...
  • Page 2 HARDWARE DRYWALL GANG BOX 7/16" (11 mm) 6ABx1-1/4" Drywall Anchors 6-32x1" 7/16" (11 mm) WHITE GREY INSTALLATION WIRE TO GARAGE DOOR OPENER MOUNT THE DOOR CONTROL WIRE THE DOOR CONTROL Install the door control within sight of the door at a minimum 1 Mark the location of the bottom mounting hole and drill a 5/32 1 Strip 7/16 inch (11 mm) of insulation from the end of the wire height of 5 feet (1.5 m) where small children cannot reach, and...
  • Page 3 Push Bar Screen Navigation Buttons Motion Sensor LIGHT Button OPERATION PUSH BAR TIMER-TO-CLOSE (TTC) LOCK Press the push bar to open or close the door. DO NOT enable TTC if operating a one-piece door. TTC is to be When the Lock feature is on, your used ONLY with sectional doors.
  • Page 4 Repeat the steps LOCK: Enable/disable lock. Raynor warrants to the first consumer purchaser of this product above for programming additional remote controls or keyless entry that is free from defect in materials and/or workmanship for a ®...