AQUA PLUS
INDIRECT
Troubleshooting
Typical problems and causes and page location for details
Problem
Insufficient
hot water
Excessive
domestic water
temperature
Boiler relief valve
lifting or weeping
Temperature/
pressure relief
valve lifting
or weeping
Water on the
floor near the
tank
Top of tank or
insulation wet
Water quality
problems
28
-
FIRED WATER HEATERS
(continued)
Check possible causes
Undersized water heater?
Boiler system improperly sized?
Check component parts.
Check boiler operating tempera-
tures.
Reduce stacking
Lower boiler operating tempera-
ture.
Undersized expansion tank?
Faulty boiler expansion tank?
Faulty boiler relief valve?
Undersized or missing domestic
water side expansion tank?
Faulty domestic water side expan-
sion tank?
Faulty T & P relief valve?
Check for leaks from sources other
than the water heater.
Check for leaks from sources other
than the water heater.
Water smells like "rotten eggs."
Milky water.
— Product Manual
Check location of flow control
devices.
Check for air in the system.
Clean the boiler water system.
Check tank thermostat setting.
Install a thermostatic mixing valve.
Install a recirculation loop.
Faulty boiler fill valve?
High domestic water supply pres-
sure?
Possible water hammering or pres-
sure spikes?
Check boiler operating tempera-
ture.
T & P relief valve lifting and dis-
charging?
Loose piping connections?
Loose piping connections?
Discolored water from the hot
water faucet.
Part number GL-E223-ADOC 0615
Page
29
32
33
34
35
35
37