Middle Atlantic Products UPS-S1500R User Manual

Middle Atlantic Products UPS-S1500R User Manual

Standard ups series

Advertisement

STANDARD UPS SERIES
RACKMOUNT UNINTERRUPTIBLE POWER SUPPLY
THANK YOU
Thank you for purchasing the Standard UPS Series rackmount UPS. The UPS provides battery
backup during power outages, automatic voltage regulation during periods of inconsistent utility
power and surge protection.
IMPORTANT
Please read this manual before removing the UPS from the shipping carton and before making any
connections to and operating your UPS.

USER MANUAL

UPS-S500R/S1000R
UPS-S1500R/S2200R
U L
C
US
R
LISTED
I-00690
Rev E

Advertisement

Table of Contents
loading

Summary of Contents for Middle Atlantic Products UPS-S1500R

  • Page 1: User Manual

    STANDARD UPS SERIES RACKMOUNT UNINTERRUPTIBLE POWER SUPPLY LISTED UPS-S500R/S1000R UPS-S1500R/S2200R THANK YOU Thank you for purchasing the Standard UPS Series rackmount UPS. The UPS provides battery backup during power outages, automatic voltage regulation during periods of inconsistent utility power and surge protection.
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Page No. Circuit Diagram ..........FCC Warning .
  • Page 3: Fcc Warning

    FCC WARNING NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
  • Page 4: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS Please read and follow all instructions carefully during installation and operation of this unit. Read this manual thoroughly before attempting to unpack, install or operate. The lightning flash with the arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
  • Page 5 CONSIGNES DE SÉCURITÉ IMPORTANTES CONSERVER CES INSTRUCTIONS S'il vous plaît lire et suivre attentivement les instructions lors de l'installation et le fonctionnement de cet appareil. Lisez ce manuel soigneusement avant de déballer, installer ou utiliser. L'éclair avec le symbole de flèche dans un triangle équilatéral est destiné à alerter l'utilisateur de la présence d'une tension dangereuse non isolée dans l'enceinte du produit qui peut être d'une ampleur suffisante pour constituer un risque de choc électrique pour les personnes Le point d'exclamation dans un triangle équilatéral est destiné...
  • Page 6: Unpacking/Parts List

    UNPACKING/PARTS LIST DO NOT LIFT THE UPS WHILE HOLDING THE FRONT FACE OF THE UNIT. THIS MAY DAMAGE THE UNIT. ALWAYS LIFT THE UPS BY HOLDING IT BY BOTH SIDES. LIFT OUT OF BOX WHILE HOLDING BOTH SIDES OF LIFT OUT OF BOX WHILE HOLDING BOTH SIDES OF The UPS is very heavy and should be handled by two (2) people.
  • Page 7 MOUNTING/INSTALLATION CONTINUED CAUTION: THIS UNIT IS HEAVY, LIFT CAREFULLY (Two person lift recommended for 2RU models) ATTENTION: Cette unité est lourde, soulevez avec precaution (Deux personne soulever recommandé pour 2RU modèles) 2) Determine mounting location. 3) Carefully lift the unit to the mounting position constantly supporting the bottom. 4) Install the front of the unit to the rackrail.
  • Page 8: Front Led Definitions

    FRONT LED DEFINITIONS UPS-S500R/S1000R SHOWN UPS-S1500R/S2200R SHOWN LED STATUS DISPLAY: a. LINE - Illuminates green when power is supplied by the AC mains. The LED will be off when the unit is battery back up mode. b. AVR - Illuminates green to indicate that the UPS is boosting the line voltage.
  • Page 9 FRONT FEATURE SET CONTINUED POWER ON/OFF PUSH BUTTON : Press to turn on or off. MUTE PUSH BUTTON: Press and hold for 2 seconds to mute the audible alarm. The ‘Mute’ LED will illuminate. Press and hold again to enable the audible alarm. BATTERY BAR GRAPH: Indicates the approximate amount of battery capacity remaining in 25% increments.
  • Page 10: Rear Panel Feature Set

    UPS-S500R/S1000R REAR FEATURE SET EXPANSION PORT: Slot for optional Network Interface Card (NIC). Part Number UPS-IPCARD. Refer to the instructions with the UPS-IPCARD for configuration. AC OUTPUT CIRCUIT BREAKERS: Resettable circuit breakers provides AC output overload protection. INPUT POWER CORD: Heavy-duty permanently attached power cord, connects UPS to mains power.
  • Page 11 UPS-S1500R/S2200R REAR FEATURE SET AC OUTLETS (BANK CONTROLLED): All AC outlets provide connected equipment with AC line power, surge protection and line noise filtering during normal operation. Automatic voltage regulation boosts low voltage without using battery power. All outlets provide battery power during blackouts and severe brownout or severe high voltage conditions.
  • Page 12: Battery Charging

    UPS-S1000R Series ESTIMATED RUNTIME (Full Load) 3 MINUTES 3 MINUTES ESTIMATED RUNTIME (Half Load) 12 MINUTES 13 MINUTES MODEL UPS-S1500R Series UPS-S2200R Series ESTIMATED RUNTIME (Full Load) 6 MINUTES 4 MINUTES 18 MINUTES 13 MINUTES ESTIMATED RUNTIME (Half Load) Page 12...
  • Page 13: Battery Replacement Warnings

    Risques d'énergie danger, 24 V, maximaux 18 ampère-heure batterie. Avant de remplacer des batteries, enlever conducteur bijoux tels que des chaînes, des montres-bracelet et des anneaux. La haute énergie par les matériaux conducteurs a pu causer les brûlures graves (UPS-S1500R/UPS-S2200R). ATTENTION: Risques d'énergie danger, 24 V, maximaux 16 ampère-heure batterie.
  • Page 14: Battery Replacement

    UPS-S500R/S1000R SERIES BATTERY REPLACEMENT 1) Gently remove the front panel. (FIGURE D) FIGURE D 2) Remove the battery access panel. Three screws for the UPS-S500R, two for the UPS-S1000R. (FIGURE E) FIGURE E 3) Disconnect the wires from the UPS to the battery.
  • Page 15 UPS-S1500R/S2200R SERIES BATTERY REPLACEMENT 1) Gently remove the front panel. (FIGURE I) FIGURE I 2) Remove the two screws affixing the battery access panel. Disconnect the wires from the UPS to the battery. (FIGURE J) FIGURE J 3) Remove the four screws that secures the battery to the UPS.
  • Page 16: Troubleshooting

    1. Battery is not fully charged. The UPS does not plugged in. perform the expected 2. Battery is degraded. 2. Contact Middle Atlantic Products about runtime. replacement batteries at 1-800-266-7225. 1. The on/off switch is designed 1. Turn the UPS off. Wait 10 seconds and then turn the UPS on.
  • Page 17 TECHNICAL SPECIFICATIONS UPS-S500R/UPS-S1000R SERIES MODEL UPS-S500R Series UPS-S1000R Series Capacity (VA) 1000 Capacity (Watts) INPUT Cord Length & Plug Type 10ft. & NEMA 5-15P Input Voltage Range 90 VAC - 140 VAC Input Frequency Range 60 Hz +/- 3 Hz (auto sensing) OUTPUT On Battery Output Simulated Sine Wave at 120 VAC +/- 10%...
  • Page 18 TECHNICAL SPECIFICATIONS UPS-S1500R/UPS-S2200R SERIES MODEL UPS-S1500R Series UPS-S2200R Series Capacity (VA) 1500 2000 Capacity (Watts) 1320 INPUT Cord Length & Plug Type 10ft. & NEMA 5-15P 10ft. & NEMA 5-20P Input Voltage Range 90 VAC - 140 VAC Input Frequency Range...
  • Page 19: Technical Specifications

    TECHNICAL SPECIFICATIONS (ALL MODELS) MODELS All Models Warning Diagnostics Power On, Wiring Fault, LED Display (Using Battery, AVR, Load Level, Indicators Battery Level) Audible Alarms On Battery, Low Battery, Overload Environmental Operating Temperature 32º F to 104º F (0º C to 40º C) Operating Relative 0 to 95% Non-Condensing Humidity...
  • Page 20: Warranty

    WARRANTY Middle Atlantic Products, Inc. (the "Company") warrants the UPS Series Uninterruptible Power Supply product to be free from defects in material or workmanship under normal use and conditions for a period of (3) three years from date of shipment by the Company, with the following exception: the internal battery is covered for (2) two years.

This manual is also suitable for:

Ups-s1000rUps-s500rUps-s2200rStandard ups series

Table of Contents