AKT 780
GB
LIGHTING THE BURNERS
•
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting
•
Press the knob against the control panel to ignite the burner.
•
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This safety device shuts off the gas if the flame goes out accidentally (draughts, interruption of gas, liquids boiling
over, etc.).
•
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the
following rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
-
In the case of pans with convex bottoms (WOK), use
the support grille provided, which should be
positioned only on the 4 ring burner.
5019 319 01619
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2.
Auxiliary burner
3.
Semirapid burner
4.
Rapid burner
5.
Semirapid burner
6.
4 ring burner
7.
Auxiliary burner control knob
8.
Semirapid burner control knob
9.
Rapid burner control knob
10. Semirapid burner control knob
11. 4 ring burner
SYMBOLS
Tap closed
Maximum flame
Minimum flame
.
Burner
Pot Ø
4 ring
from 24 to 26 cm
Rapid
from 24 to 26 cm
Semirapid
from 16 to 22 cm
Auxiliary
from 8 to 14 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
DIMENSIONS AND DISTANCES TO BE MANTAINED (mm)
NOTE:
If the distance "A" between the wall cabinets is between 600 mm and 730 mm, the height "B"
must be a minimum of 520 mm. if the distance "A" between the wall cabinets is greater than
the width of the hob, the height "B" must be a minimum of 400 mm.
In case of installation of a hood above the hob, please refer to the hood instructions for the
correct distance.
INJECTOR TABLE
Type of gas used
Type of
Injector
burner
marking
4 ring
139
NATURAL GAS
Rapid
128
Semirapid
95
(Methane)
G20
Auxiliary
78
LIQUEFIED
4 ring
95
PETROLEUM GAS
Rapid
87
(Butane)
G30
Semirapid
67
Auxiliary
50
(Propane)
G31
Type of gas
Model
Rated thermal flow
used
configuration
rate kW
G20 20 mbar
5 burners
G30/G3130 mbar
5 burners
ELECTRIC SUPPLY: 230 V ~ 50 Hz
BG
RO
HR
SR
CATEGORY II2H3B/P
Rated
Rated
Reduced heat
Gas pressure mbar
thermal
consumption
capacity kW
min.
flowrate kW
3.50
333 l/h
1.55
3.00
286 l/h
0.60
17
1.65
157 l/h
0.35
1.00
95 l/h
0.30
3.50
254 g/h
1.55
3.00
218 g/h
0.60
25
1.65
120 g/h
0.35
1.00
73 g/h
0.30
Total rated
Air required (m
consumption
burning 1 m
10.8
1028 l/h
10.8
785 g/h
SL
TR
MA
rat.
max.
20
25
30
35
3
) for
3
of gas
9.52
30.94