Lighting Your Furnace
CAUTION
!
This furnace is equipped with an interrupted type
electronic ignition system. DO NOT ATTEMPT TO
LIGHT WITH A MATCH.
DANGER!
!
HIGH VOLTAGE AT IGNITOR.
1. This appliance is equipped with an ignition device which
automatically lights the burner. Do NOT try to light the
burner by hand.
2. After preparing the furnace for heating operation (See pre-
vious section) and checking for oil, proceed as follows.
3. For a heating/cooling system, set the thermostat to HEAT
and the fan to AUTO. Set the thermostat to the desired
room temperature and TURN ON the electrical power to
the furnace.
4. The burner should light and the system should be controlled
by the thermostat.
Turning Off Your Furnace
Follow these simple procedures to put your furnace into retire-
ment for the summer.
1. Set the thermostat to the lowest setting.
2. TURN OFF all electric power to the appliance.
3. Turn the oil supply OFF.
4. If applicable, TURN OFF water supply to humidifier.
5. If furnace blower will be necessary for cooling system, re-
member to turn electric power back ON when needed for air
conditioning.

MAINTAINING YOUR UNIT

The life of your system depends on the care you give it. Proper
care assures good performance; lack of it can damage the unit.
Here are the things you should do, or have your dealer service
technician do for you.
NOTE: Before you start, TURN OFF all electrical power to
unit and turn thermostat to OFF.
Filters
A filter is supplied with the furnace (except 58BGA). It is
NECESSARY THAT ALL FURNACES BE EQUIPPED
WITH A FILTER.
If a different type of filter is used, it must be an equivalent high
airflow capacity
yyy
.
yyy
!
Never operate unit without a filter or with filter ac-
cess door removed. Failure to adhere to this warn-
ing could lead to a hazardous condition which
could lead to equipment damage and bodily harm.
Keeping Filters Clean
As a homeowner, this is your most important responsibility. A
dirty filter reduces the efficiency of your system, causes erratic
performance of controls, and could result in damage to the mo-
tor or heat exchanger.
1. Inspect filters at regular intervals depending upon dirt con-
ditions. For new homes, check filters every week for 4 con-
secutive weeks. In all cases, inspect your filters at least every
3 to 4 weeks when the system is in constant operation. Re-
place or clean filter at least at the beginning of each season
(heating & cooling) and thereafter as needed.
2. If the permanent filter supplied with the unit becomes dirty,
it can be cleaned with cold water and soap.
Be sure that the filter is thoroughly dry before installing back
into the furnace.
Lubricating Motors
Direct drive motor and blower assemblies are factory lubri-
cated and normally do not require oiling. If oiling is required,
lubrication of the blower motor is to be performed only by a
qualified service agency.