Download Print this page

Whirlpool 3402328 Installation Instructions Manual page 9

Advertisement

Remove
the red caps from the gas
pipes.
11.
Connect
gas supply to each
dryer.
Use pipe-joint
compound
resistant to
the action
of Natural and L.P. gas for
gas connections.
12.
Open the shutoff valves in the gas
supply lines.
Fire Hazard
Do Not use an open flame to test
tar leaks from gas connectlons.
Checking for leaks wlth a flame
may result In a tire or explosion.
13.
Use a brush and liquid detergent
to
test all gas connections
for leaks.
Bubbles around
connections
will
indicate
a leak. If a leak appears,
shut off gas valve
controls and adjust
connections.
Then check
connections
again.
NEVER TEST FOR
GAS LEAKS WITH A FLAME.
Close the
access
panels.
All connectlons
must be wrench-
tightened.
Plug power supply cords into
grounded
outlets, Turn on electrical
power supply.
Betore movlng dryers across floor,
slide dryers onto cardboard or
hardboard to protect rloor coverlng.
Move unit to its permanent
location.
15.
Turn one dryer on to remove
air from
the gas supply line. Using a full heat
cycle
(not the air cycle),
let the dryer
run for at least five minutes.
If the
burner does not ignite and you can
feel no heat inside the dryer, shut off
the dryer for five minutes. Check that
all supply valve controls are In "ON"
position and that the power
supply
cord is plugged
in. Repeat
the five-
minute test.
16
n
Check levelness of dryers by placing
a carpenter's
level on top of the
dryers or collar, first side to side, then
front to back. If dryer Is not level.
adjust the front legs up or down.
Make the final check
with the level.
17.
To exhaust
the dryers, see "Exhaust
requirements"
and "Exhaust duct
connection,"
Pages 5 and 6.
Injury Hazard
To prevent tlpplng, tether bracket
must be secured to wall studs or
concrete wall.
Failure to do so could result In
InJury.
tether bracket
lo
at rear of the top
Attach
both ends of tether located
at
the rear of the top drver to a secured
,
,
2 x4.