Norcold N62X Installation Instructions Manual
Norcold N62X Installation Instructions Manual

Norcold N62X Installation Instructions Manual

Hide thumbs Also See for N62X:

Advertisement

For N62X and N62XXX models:
For N64X and N64XXX models:
For N64XIM and N64XIMXX models:
For N82X and N82XXX models:
For N84X and N84XXX models:
For N84XIM and N84XIMXX models:
The model numbers of 3-way refrigerators include ".3". The model numbers of 2-way refrigera-
tors do not.
WARNING:
can cause injury or property damage. Refer to this manual. For assis-
tance or additional information, contact a qualified installer, service
agency, or the gas supplier.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquid in
the vicinity of this or any other appliance.
FOR YOUR SAFETY
If you smell gas:
WARNING:
DO NOT install this refrigerator in below deck marine
applications. Do not install this refrigerator in a fixed indoor cabin or
other dwelling applications. This refrigerator must use only
NORCOLD designed and approved outside air intake and exhaust
ventilation for correct and safe operation. Any other ventilation could
cause lethal combustion exhaust fumes and/or explosive propane
gas fumes to be in the living area and/or to be below deck.
NORCOLD, Inc.
P.O. Box 4248
Sidney, OH 45365-4248
6 cu.ft., 2-way, R.V. refrigerators.
6 cu.ft., 2-way or 3-way, R.V. refrigerators.
6 cu.ft., 2 way, R.V. refrigerators with ice maker.
8 cu.ft., 2-way, R.V. refrigerators.
8 cu.ft., 2-way or 3-way, R.V. refrigerators.
8 cu.ft., 2-way, R.V. refrigerators with ice maker.
Improper installation, adjustment, alteration, service or maintenance
1. Open windows.
2. Don't touch electrical switches.
3. Extinguish any open flame.
4. Immediately call your gas supplier.

Installation Manual

English
French
Part No. 621831J (7-03)

Advertisement

Table of Contents
loading

Summary of Contents for Norcold N62X

  • Page 1: Installation Manual

    Do not install this refrigerator in a fixed indoor cabin or other dwelling applications. This refrigerator must use only English NORCOLD designed and approved outside air intake and exhaust ventilation for correct and safe operation. Any other ventilation could cause lethal combustion exhaust fumes and/or explosive propane gas fumes to be in the living area and/or to be below deck.
  • Page 2: Table Of Contents

    Do a test of the gas safety valve ......... 11 supply line connections. Shut down-all models ............11 Fault Codes (N62X, N62XX, N82X, and N82XX models) ..12 - Make sure the electrical installation obeys all applicable Fault Codes (N64X, N64XXX, N64XIM, N64XIMXX, codes.
  • Page 3: Certification And Code Requirements

    The installation must obey these standards and this use of baffles and panel construction. “Installation Manual” for the NORCOLD limited warranty to be in effect. Installation must conform with the following as Certified installation needs one lower intake vent and one upper applicable: exhaust vent.
  • Page 4: Assemble The Enclosure For The Refrigerator

    N82X, N82XXX, N84X, N84XXX, N84XIM, and N84XIMXX prevent the refrigerator from operating correctly. models or 52.88 - 53.01 inches high for N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models x 23.50 - NOTE: Tighten the screws of the upper roof exhaust cap to 10 23.63 inches wide x 24.00 inches deep.
  • Page 5 - Make sure that the baffles are the full width of the inside of the enclosure. - For N62X, N62XXX, N64X, N64XXX, N64XIM, and N64XIMXX models, make sure the distance [14] - If the depth of the enclosure is more than 26 inches, install...
  • Page 6: Install The Decorative Door Panels (Nonmetal Door Models)

    - 21 19/32 inches wide and the lower rear corner of the condenser and the baffle. - 31 5/8 inches high (for N62X, N64X, and N64XIM models) or - If the depth of the enclosure is more than 26 inches...
  • Page 7: Reverse The Door Swing (Optional)

    - Reverse the front box and put it on the opposite side of the - Push the bottom trim piece [15] onto the front of the refrig- erator. controls. - Put two screws [16] through the trim piece, the mounting - Attach the front box to the refrigerator with the screw.
  • Page 8: Connect The Ice Maker (N64Xim, N64Ximxx, N84Xim, And N84Ximxx Models)

    - For copper tubing, use the brass sleeve. - Put each hinge bushing into the bottom side of each door hinge. - For plastic tubing, use the plastic sleeve [2]. - Put each door in the position on the refrigerator. - For plastic tubing with .040 in.
  • Page 9: Connect The 12 Volts Dc Supply

    ANSI A 119.2 (NFPA 1192) and CSA Z240 Standards on Recreational Vehicles. Norcold - Put fuse as close to the battery as possible. recommends the use of 3/8 inch copper tubing as the gas supply line and requires a 3/8 inch SAE (UNF 5/8-18) male 3.
  • Page 10: Examine The Gas Supply System For Leaks

    “FL” appears in the center display. This means that the gas did Ignition and start up: not ignite. (N62X, N62XX, N82X, and N82XXX models) (See Art01019) If the gas does not ignite after several attempts, refer to the “Fault Codes” section of this manual.
  • Page 11: Do A Test Of The Gas Safety Valve

    In Stand By Mode, the code “F” appears in the center display. This means that the gas did not ignite. If the gas does not ignite after several attempts, refer to the “Fault Codes” section of this manual. Automatic Mode Operation: 1.
  • Page 12: Fault Codes (N62X, N62Xx, N82X, And N82Xx Models)

    Fault Codes (N62X, N62XXX, N82X, and N82XXX models) t l u t l u i t c a t l a l i . l a f i ( c i l " " d " " F t i n n i l "...
  • Page 13: N84X, N84Xxx, N84Xim, And N84Ximxx Models)

    Fault Codes (N64X, N64XXX, N64XIM, N64XIMXX, N84X, N84XXX, N84XIM, and N84XIMXX models) t l u t l u i t c a t l a l i . l a f i ( c i l " " r " "...

Table of Contents