LG LFX28978 series Service Manual page 29

Hide thumbs Also See for LFX28978 series:
Table of Contents

Advertisement

8-5 Defrost Heater Error (Er dH)
No
1
Check the Door gasket.
2
Check the Defrost control part.
3
Input Test 3 Mode.
(Push the button 3 times)
4
Check the Blue to Orange.
<CON3>
5
Release the test mode.
Push the button 1 times. (Normal)
6
Check the Blue to Orange.
<CON3>
Checking flow
Fuse
M
Def Heater
Result & SVC Action
Part
Fuse-M
Def
34~42
Def
Sensor
Heater
Def
Sensor
Result
112 ~ 116 V
0 V
Result
0 V
112 ~ 116 V
- 29 -
Result
SVC Action
Go to the 3
0
Change Fuse-M
Go to the 3
Change Fuse-M
Go to the 3
0
Replace product
OFF
SVC Action
Go to the 5
Replace Main PCB
SVC Action
Explain to customer
Replace Main PCB

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lfx25978 series