Sub Pwb For Working Dispenser; Cap Duct Motor Replacement - LG LFX28978 series Service Manual

Hide thumbs Also See for LFX28978 series:
Table of Contents

Advertisement

CAUTION: Make sure that the motor housing is taped to
the mold, if not positioned correctly the cover will not fit
properly.

3-15 SUB PWB FOR WORKING DISPENSER

1) Disconnect the wire harness.
Figure 37
2) Remove 1 screw from PWB and replace with new PWB.
Figure 38

3-16 CAP DUCT MOTOR REPLACEMENT

1) Separate the Housing of the Cap Duct Motor.
2) Unscrew 3 screws to disassemble the motor.
Figure 36
3) When replacing the motor, check the position of the door
duct and the link for proper fit.
4) Insert 2 screws.
5) Push housing aside.
- 12 -
Figure 39
Figure 40
Duct Door
Link
Cap Duct Motor
NG Position
Figure 41
Figure 42
Figure 43

Hide quick links: