Battery - Honda EX5500 Owner's Manual

Hide thumbs Also See for EX5500:
Table of Contents

Advertisement

Battery
The generator's
engine has a 1 amp charging system to charge the
battery while the engine
is running.
If the generator
is only. used
periodically,
the battery must be charged
monthly
to maintain
the
battery service life.
A lead acid battery self discharges at a rate of 0.5-
1 .O% per day. This
means that the battery, if the generator
is not operated in a month,
can discharge as much as 30% in the same period. This could cause
the engine not to crank or shorten the service life of the battery. To
charge the battery, follow the procedures below.
Removal:
1. Open the battery cover.
2. Remove the battery set plate.
3.Remove
the negative
(-1
cable from
the battery
negative
(-)
terminal;
then
remove
the positive
(+)
cable from the battery
positive (+) terminal.
. PLATE
BAlTERY
SE1
BATTERY COVER
4.Remove
the battery from the
battery tray.
Inspection:
1. Remove the battery cell caps.
2.lnspect the electrolyte
level of
each cell. The electrolyte
level
must be maintained
between
the UPPER and LOWER level
marks.
UPPER LEVEL
3.lf the electrolyte
level is near
the LOWER mark, add distilled
water as necessary.
LOWER LEVEL