Whirlpool UXT5230AY Installation Instructions And Use & Care Manual page 13

30" (76.2 cm) and 36" (91.4 cm) range hood
Table of Contents

Advertisement

Available languages

Available languages

To Replace the Filter:
1. To reinstall the lter, the single slot opening on the long edge
of the lter is to be toward the front of the range hood. Place
the back edge of the lter into the channel at the rear of the
range hood.
2. Pull the lter retainer toward the front of the range hood and
push the front of the lter up into place.
3. Release the lter retainer. It will spring back into place to
secure the lter.
4. Replace the screw into the lter retainer.
Replacing the Halogen Lamp
Turn off the range hood and allow the halogen lamp to cool. To
avoid damage or decreasing the life of the new lamp, do not
touch lamp with bare ngers. Replace lamp, using tissue or
wearing cotton gloves to handle lamp.
If new lamps do not operate, make sure the lamps are inserted
correctly before calling service.
1. Disconnect power.
2. Use a at-blade screwdriver and gently pry the light cover
loose.
3. Remove the lamp and replace with a 120-volt, 40-watt
maximum, halogen lamp made for a G-9 base.
4. Replace the light cover.
5. Reconnect power.
13