3-2 Controls and Components
Operating mode
selection dial
3-2-1 Thermostat
OFF
When the room temperature is lowered by the air condition-
er, the gas within the thermostat will contract and cause a
break in the electric contact. The compressor will then stop.
After the compressor stops, the room temperature will rise
ON
As the room temperature increases to a selected level,
the gas within the thermostat expands, causing electric
contact, which provides the source of electric power to the
compressor. The room temperature will fall and the cycle will
repeat.
Samsung Electronics
3-2-1 Thermostat
Control Operation
By turning the control knob clockwise(toward higher
numbers), the temperatures will be cooler.
By turning the control knob counterclockwise (toward lower
numbers), the temperature will be warmer.
Level 01 : Cool air will be supplied above 30~35˚
Level 10 :
Cool air will be ceased below 28~32.5˚
Level 10 : Cool air will be supplied above 17.4~20.4˚
Level 10 :
Cool air will be ceased below 14.4~17.4˚
Temperature
control dial
Air flow blade swing switch
7