FINISHING MATERIAL
NOTE: Any remote wiring (i.e. remote control, wall switch, and optional fan) must be done prior to final
finishing to avoid costly reconstruction.
Never obstruct or modify the air inlet or outlet grills (louvers). This may create a
fire hazard.
Only noncombustible materials (i.e. brick, tile, slate, steel, or other materials with a UL fire rating of Zero) may be used to
cover the black-painted face of the appliance. A 300°F minimum adhesive may be used to attach facing materials to the black
surface. If joints between the finished wall and the fireplace surround are sealed, a 300°F minimum sealant material (General
Electric RTV103 or equivalent) must be used. Combustibles may come to the top and side edges but not overlay the face.
VENT INSTALLATION
Read all instructions completely and thoroughly before attempting installation. Failure
to do so could result in serious injury, property damage or loss of life. Operation of
improperly installed and maintained venting system could result in serious injury,
property damage or loss of life.
INSTALLATION PRECAUTIONS
NOTE: This appliance must be installed with a Monessen approved venting system only.
Consult local building codes before beginning the installation. The installer must make sure to select the proper vent system
for installation. Before installing vent kit, the installer must read this fireplace manual and vent kit instructions.
Only a qualified installer/service person should install venting system. The installer must follow these safety rules:
• Wear gloves and safety glasses for protection.
• Use extreme caution when using ladders or when on rooftops.
• Be aware of electrical wiring locations in walls and ceilings.
The following actions will void the warranty on your venting system:
• Installation of any damaged venting component.
• Unauthorized modification of the venting system.
• Installation of any component part not manufactured or approved by Monessen.
• Installation other than permitted by these instructions.
42D0200
Failure to follow these instructions will
void the warranty.