SECURING FIREPLACE TO FLOOR
The fireplace must be secured to the floor and/or to framing studs as shown in Figure 10. Use two (2) wood screws or
masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing. The side brackets
are adjustable from 1/2" to 5/8" to accommodate different thickness of noncombustible material.
42D0200
The fireplace must be installed giving full
consideration to the clearance and height
requirements identified in this manual.
Figure 10 - Securing Fireplace to Floor and Framing Studs
SECURING FIREPLACE TO FLOOR
Screws
13