Connecting to the water supply

Permitted water pressure

The water pressure must be at least 1bar (=10N/cm
be a maximum of 10bar (=100N/cm
– If more than 10bar: Connect a pressure reduction valve.
– If less than 1bar: Disconnect the appliance end of the inlet hose from
the solenoid inlet valve and remove the flow meter. (In addition re-
move the filter using pointed pliers and take out the rubber gasket
behind it.) Re-insert the filter.

Water inlet

Attention!
• An inlet hose is supplied and can be found inside the machine drum.
• Do not use the hose from your previous machine to connect to
the water supply.
• This appliance must be connected to a cold water supply.
1. Open the porthole and extract the inlet hose.
2. Connect the hose with the angled
connection to the machine.
Important!
Do not place the inlet hose down-
wards. Angle the hose to the left
or right depending on the position
of your water tap.
3. Set the hose correctly by loosening
the ring nut. After positioning the
inlet hose, be sure to tighten the
ring nut again to prevent leaks.
32
2
=0.1MPa) and may
2
=1MPa).