Safety Thermostat; Function; Checks; Removal - Biasi M110B.24SM/E Service Manual

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

19

SAfETy THERMoSTAT

19.1 function

The safety thermostat A in Figure 19.1 is a device that senses
the temperature of the primary circuit water which flows in the
outlet pipe of the condensing heat exchanger.
If the temperature control system of the boiler fails and the tem-
perature of the primary circuit reaches a dangerous temperature,
the safety thermostat opens the electric circuit that supplies the
on-off operators of the gas valve.
Consequently, the full sequence ignition device attempts to light
the burner and, at the end, locks the boiler and lights the lock-out
signal lamp.
figure 19.1

19.2 Checks

Overheat temperature value
1 Set the temperature control knobs to their max. position and
run the boiler in d.h.w. and c.h.
2 Allow the boiler to reach its maximum operating temperature
(monitor the temperature gauge on the instrument panel).
The boiler should maintain a temperature below that of the
safety thermostat and no overheat intervention should occur.
Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent.
Electrical function
1 Remove all the case panels and the lid of the sealed cham-
ber.
2 Disconnect the safety thermostat and check its electrical
function. Normally (no intervention) the contact must be
closed (electrical resistance zero Ω).
SAfETy THERMoSTAT
A

19.3 Removal

Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent.
1 Remove all the case panels and the lid of the sealed cham-
ber.
2 Disconnect the wiring B (detail in Figure 19.2).
3 Unscrew the screws C which hold the overheat thermostat
on the pipe of the condensing heat exchanger and remove it.
C
B
figure 19.2
4 Reassemble the overheat thermostat carrying out the opera-
tions in reverse order.
5 Apply an adequate quantity of heat conducting compound
between the pipe and the thermostat.
Warning: After cleaning or replacement as detailed
above, if it deemed necessary to undertake a com-
bustion analysis as detailed in section "Adjust-
ment" page 25.
- 39 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

M110b.32sm/e

Table of Contents