Connecting The Humidifying Hose; Setting The Humidifying Hose Length - Daikin FTXZ25NV1B Installation Manual

R32 split series
Hide thumbs Also See for FTXZ25NV1B:
Table of Contents

Advertisement

8.

Connecting the humidifying hose

• If the air conditioner is operated without the
short-circuit on the printed circuit board. Be sure to connect it.
1) Connect the
humidifying hose to the outdoor humidifying duct.
G
2) Apply a
binding band to prevent the
K
Outdoor
humidifying
duct
G
Humidifying
hose
Binding part of binding band
G
Humidifying hose
K
Binding band
9.

Setting the humidifying hose length

• Set the humidifying hose length to ensure humidifying capacity.
Use the remote controller to set the humidifying hose length.
When doing this, power on the unit as communication is established between the unit and the remote controller.
1) Press
for at least 5 seconds.
• The default menu is displayed.
• To exit the menu, press
2) Press
. Select "Hose length".
3) Press
to enter the humidifying hose length setting mode.
• Be sure to direct the remote controller toward the indoor unit.
• The currently set humidifying hose length will be displayed. (No setting is made by default.)
4) Press
and set the humidifying hose length.
The humidifying hose length can be set in 5 stages:
3M
5) When you set the humidifying hose length, press
• Direct the remote controller toward the indoor unit.
6) Press
.
• The setting of the humidifying hose length is complete.
• If you set the humidifying hose length incorrectly, cancel the setting with "Length Reset" at step 4), and then set the length again.
When the humidifying hose length is already set, only reset is displayed at step 4).
• Incorrectly setting the humidifying hose can cause poor performance and noise. Be sure to set it. (When not set, error code "UA" will
be displayed.)
< When the unit cannot be powered on >
• When you set the humidifying hose length without powering on the indoor unit.
In the above step 3), "Receive failure" is displayed.
However, with the operations of steps 4) and 5), "Length set" is displayed, and the humidifying hose length is saved in the remote
controller.
The error code "H" should be displayed during the operations of steps 4) and 5).
• When you operate the air conditioner, the humidifying hose length will be sent to the indoor unit and the humidifying hose length will
be set.
humidifying hose connected, humidifi ed air fi lls the outdoor unit and may cause a
G
humidifying hose from coming off.
G
Attach the
humidifying
G
hose, making sure there is
no gap.
Apply the
K
binding band at
10mm from the top of the
G
humidifying hose to prevent
the hose from coming off.
Turn the binding part of the
to the outdoor unit side.
(It is easier to attach the stop valve cover.)
or leave it unoperated for 60 seconds. The display will return to the normal display.
3.1M 4M
4.1M 6M
.
Section A
If this barrier exists in the back of the
stop valve cover, cut sections A and
B and bend the barrier upward.
Stop valve cover
binding band
K
6.1M 8M
8.1M 10M
Section B
16
16

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rxz35nv1bFtxz35nv1bRxz50nv1bFtxz50nv1bRxz25nv1b

Table of Contents