ELECTRICAL SYSTEM
FUSE. Continued
The electrolyte
(acid and water) in each cell should
be at ring
level at all times
to
prevent
battery
failure.
When the electrolyte
is below this
level,
add pure, distilled water.
NOTE: There are two fuses adjacent to the lighting
switch on the tractor pedestal (left side). The lower
fuse is for the lights; the upper fuse is for the
electric clutch.
Acid or electrolyte should never be added except
by a skilled battery man. Under no circumstances
add any special battery
"dopes",
solutions or
powders.
To
install a new fuse, press in on the fuse housing
cap and turn counterclockwise
to remove it from
the fuse housing. Remove the old fuse and replace
it with a new one. Then reassemble the cap to the
housing.
CAUTION!
If the tractor is to be tipped
up or on its side remove the batteries to
avoid spilling
the electroyte.
Battery
electrolyte
is poisonous and can be injurious to
eyes, skin, and clothing.
If electrolyte
is spilled,
flush
immediately
with
water, followed
by a
solution
of one part baking soda to four partswater.
Before working
on any part of the electrical
system, disconnect the battery ground cable at the
battery negative (-j terminal. Do not reconnect this
cable until all work has been completed. This will
prevent shorting and damage to any of the elec-
trical units. Examine the electrcial cables occa-
sionally to be sure they are not being frayed by
contact with adjacent parts.
Connecting Booster Batteries
When replacing a battery, make certain the ground
cable is connected to the negative (-) terminal on
the battery. Be su re the rubber boot is properly
positioned over the positive (+) terminal on the
battery.
NOTE: Both cables must be assembled
with the nuts to the inside of the terminals to
prevent shorting against fender well.
When required, a booster 12-volt battery may be
connected in parallel with the 12-volt system on
I nternational Cub Cadet Tractors.
CAUTION!
Gas discharged by batteries
is explosive.
Avoid
sparks near the
batteries.
Cleaning and Servicing the Battery
NOTE:
All
circuits
must be turned
"off".
Elec-
trical
system
is NEGATIVE
(-) grounded
only.
Reversed polarity
will result in permanent
damage
to components
of the electricat system.
Occasionally
remove
the
battery
cables and
brighten the terminal
contact surfaces with wire
wool, and reassemble them. Apply a light coat of
vaseline or chassis lubricant. Be sure the terminals
are clamped
tightely
and that the battery
is
fastened securely in the battery
box. Replace
unserviceable cable. Keep the vent holes in the
battery filler caps open.
The first jumper cable must connect the positive
(+) terminal of the booster battery and the positive
terminal of the battery on the tractor.
Keeping the battery fully charged not only adds to
its life but makes it available for instant use when
needed.
The second jumper cable must first be connected
to the negative (-) terminal of the booster battery;
and then to a point on the frame of the tractor,
away from the battery, having a good ground, so
no spark occurs near the battery.
Liquid
Level
Check the battery
at least once a month for
electrolyte level.
For
dependable
battery
service, see your
I nter-
national Harvester dealer.