Sharp AE-X2M14LR Service Manual page 29

Muliti split type room air conditioners (outdoor unit)
Table of Contents

Advertisement

13.Remove the 3 screws fixing the coil for PFC then remove it
NOTE: When the coil re-install, silicone grease must be paste to the
back face of the coil.
14.Remove the 3 strings on the compressor cover A then remove it
15.Remove the 6 thermistors on copper tube.
NOTE: Caution to position when re-installing.
Refer to page 5-5 (Mounting position of thermistors and expansion
valves)
TH8 (BROWN)
(Just on the tilted pipe)
TH7 (WHITE)
(Just on the horizontal pipe)
TH6 (BLUE)
(Just on the horizontal pipe)
TH3 (GREEN)
TH4 (BLACK)
TH2 (ORANGE)
How to disassemble the control box assembly
16.Cut the 3 wire fixing bands.
Disconnect the 7 connectors. [CN6, CN15, CN9A, CN16, CN17,
CN5, CN101 (IPM)]
Lift up the Control Board Unit (PWB) and remove it.
Install this SHAORT-CIRCUIT CONNECTOR in a new
CONTROL PWB at CONTROL PWB exchange.
17.Disconnect the 2 terminals (Blue and Brown).
And Remove the 3 screws fixing the terminal board angle assembly
then turn it inside out.
5 – 3
AEX2M14LR
Control board unit
Blue
Brown

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents