Mineral Buildup orSediment
MayAccumulate
• This causes the water heater to become
much heavier than normal.
• If spilled, could causestaining
Mineral buildup or sediment may have accumulated
in the old
water heater. This causes the water heater to be much heavier
than normal and this residue, if spilled out, could cause staining.
Facts to Consider
About the Location
You should carefully choose an indoor location for the new water
heater, because the placement is a very important consideration
for the safety of the occupants in the building and for the most
economical
use of the appliance.
This water
heater is not
intended for outdoor installation.
Whether replacing an old water heater or putting the water heater
in a new location, the following critical points must be observed.
The location selected should be indoors as close to and as
centralized with the water piping system as possible. This
water heater, as welt as all water heaters, wilt eventually leak.
Do not install without adequate drainage provisions so water
flow will not cause damage.
Property Damage
Hazard
• All water heaters eventually leak
• Do not install without adequate drainage.
WATER HEATERS EVENTUALLY LEAK: Installation of the water
heater must be accomplished in such a manner that if the tank
or any connections should leak, the flow of water wilt not cause
damage to the structure. When such locations cannot be avoided,
a suitable metal drain pan should be installed under the water
heater. Drain pans are available at your local Sears stores. Such
drain pans must be piped to an adequate drain.
Water heater life depends upon water quality, water pressure
and the environment in which the water heater is installed. Water
heaters are sometimes installed in locations where leakage may
result in property damage, even with the use of a metal drain pan
piped to a drain. However, unanticipated damage can be reduced
or prevented by a leak detector or water shut-off device used
in conjunction with a piped metal drain pan. These devices are
available from some plumbing supply wholesalers and retailers,
and detect and react to leakage in various ways:
• Sensors mounted inthe metal drain pan thattriggeran alarm orturn
offthe incoming water tothewater heaterwhen leakage is detected.
• Sensors
mounted
in the metal drain pan that turn off the
water supply to the entire home when water is detected in the
drain pan.
• Water supply shut-off devices that activate based on the water
pressure differential between the cold water and hot water pipes
connected to the water heater.
Installations in Residential Garages
• Water
heater
must
be located
in a
protective area.
INSTALLATION IN RESIDENTIAL GARAGES: The water heater
must be located and/or protected so it is not subject to physical
damage by a moving vehicle.
• The location selection must provide adequate clearances for
servicing and proper operation of the water heater.
Insulation
Blankets
Insulation blankets are available to the general public for external
use on electric water heaters but are not necessary with this
product.
The purpose of an insulation blanket is to reduce
the standby heat loss encountered
with storage tank heaters.
Your water heater meets or exceeds the National Appliance
Energy Conversation Act standards with respect to insulation
and standby loss requirements,
making an insulation blanket
unnecessary.
Should you choose to apply an insulation blanket to this heater,
you should follow these instructions below. Failure to follow these
instructions can result in fire, serious personal injury, or death.
Do not cover the temperature and pressure relief (T & P) valve
with an insulation blanket.
Do not cover the instruction manual.
Keep it on the side of
the water heater or nearby for future reference.
D._Qo obtain new warning and instruction labels for placement
on the blanket directly over the existing labels.