Specifications - Ashly MFA-6000 Operating Manual

Ashly audio corporation operating manual power amplifier mfa-8000, mfa-6000
Table of Contents

Advertisement

Operating Manual - MFA-8000 and MFA-6000 Power Amplifier
13.

SPECIFICATIONS

13.1
Output Power
Per channel, both channels driven at 1KHz, < .1%
THD, 120VAC 60Hz
MFA-8000
8 :
750W
4 :
1200W
2 :
1500W
bridged mono mode
8 :
2400W
4 :
3000W
per channel from 20Hz to 12KHz*, < .25% THD
8 :
720W
4 :
1100W
13.2
Frequency Response:
+0/-3dB 8Hz - 100KHz
13.3
Total Harmonic Distortion:
(720W [450W for MFA-6000] into 8 , 20Hz -
1KHz, increasing to < .25% at 12KHz)
13.4
Output Hum And Noise:
-105 dB from full output
(20Hz - 20KHz unweighted)
13.5
Damping Factor:
> 200 into 8 , 20Hz - 1KHz
13.6
Crosstalk:
-90dB, 20Hz - 1KHz
13.7
Input Sensitivity:
1 Vrms for full output (MFA-8000)
0.81 Vrms for full output (MFA-6000)
13.8
Voltage Gain:
80
= 38dB
16
MFA-6000
525W
800W
900W
1600W
1800W ( 1dB)
450W
700W
0.2dB 20Hz - 20KHz
< 0.025%
13.9
Input Impedance:
20K
balanced
13.10 Amplifier Protection:
Fuseless Short-circuit protection, ultrasonic and
RF protection, advanced thermal protection.
13.11 Load Protection:
Turn-on delay relay with level ramp-up, DC fault
protection, ultrasonic limiting, clip limiting.
13.12 Cooling:
Forced air with 2-speed fan.
13.13 Indicators:
11 segment level meters with true clipping top
LED. LIMIT LED indicates when electronic
attenuator is active, THERM LED indicates a
higher than normal operating temperature and
PROTECT LED indicates when output relay is
open.
13.14 Power Requirements:
120 VAC, 50-60 Hz (240VAC available)
Maximum current draw for typical stereo
operation into 4
loads:
MFA-8000
12 amps
Idle current draw:
1.2 Amps
13.15 Size:
19"W x 5.25"H x 16.5"D
13.16 Shipping Weight:
68lbs. (61lbs.)
*Protection circuits will prevent full output
voltage above 12KHz.
MFA-6000
10 amps
1 Amp

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfa-8000

Table of Contents