DECORATIVE SERIES
CEILING VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended
by the manufacturer. If you have questions,
contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch
power off at service panel and lock the ser-
vice disconnecting means to prevent power
from being switched on accidentally. When
the service disconnecting means cannot be
locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be
done by a qualified person(s) in accordance
with all applicable codes and standards,
including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combus-
tion and exhausting of gases through the flue
(chimney) of fuel burning equipment to prevent
backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards
such as those published by the National Fire
Protection Association (NFPA), and the Ameri-
can Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the
local code authorities.
5. When cutting or drilling into wall or ceiling, do
not damage electrical wiring and other hidden
utilities.
6. Ducted fans must always be vented to the
outdoors.
7. NEVER place a switch where it can be
reached from a tub or shower.
8. This unit must be grounded.
9. This unit is U.L. listed. Type I.C. inherently
protected.
!
CAUTION
1. For general ventilating use only. Do not use
to exhaust hazardous or explosive materials
and vapors.
2. This product is designed for installation in
FLAT CEILINGS ONLY. Do not mount this
product in a wall.
3. The light fixture assembly must be mounted
to the fan housing assembly included with
this product. Do not mount the light fixture
assembly to a wiring outlet box.
4. To avoid motor bearing damage and noisy
and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
5. Please read specification label on product for
further information and requirements.

TYPICAL INSTALLATIONS

HOUSING MOUNTED
DIRECTLY TO JOIST
2x6 (or larger)
Discharge parallel to joists.
HOUSING MOUNTED
TO 2x4 TRUSS
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge parallel to joists.
*
Additional framing must be a 2x6 (minimum height).
Installer: Leave this manual with the homeowner.
Homeowner: Use and Care information on page 4.
MODELS 757PT • 757SN
HOUSING MOUNTED
TO ADDITIONAL FRAMING
Discharge 90
*
HOUSING MOUNTED TO 2x4
Requires additional framing
for mounting tabs.
Discharge 90
*
HOUSING MOUNTED TO "I" JOIST
Requires additional framing
for mounting tabs.
Discharge 90
Page 1
*
to joists.
0
*
TRUSS
to joists.
0
*
to joists.
0

Advertisement

Table of Contents
loading

Summary of Contents for Broan 757PT

  • Page 1: Typical Installations

    MODELS 757PT • 757SN Page 1 DECORATIVE SERIES CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS WARNING TYPICAL INSTALLATIONS TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Use this unit only in the manner intended by the manufacturer.
  • Page 2: Existing Construction

    MODELS 757PT • 757SN Page 2 TYPICAL INSTALLATIONS INSTALL THE HOUSING (continued) (continued) New Construction SUSPENDED CEILINGS Housing hung with wires - 3-point mount. INSTALL THE HOUSING 3. Set housing aside and drive nails partially into joist at the top of both keyhole marks.
  • Page 3: Connect The Wiring

    MODELS 757PT • 757SN Page 3 INSTALL THE HOUSING CONNECT THE WIRING (continued) SCHEMATIC WIRING DIAGRAM L I G H T R E D B L U W H T L I G H T Existing Construction S W I T C H...
  • Page 4: Service Parts

    BROAN-NUTONE ONE YEAR LIMITED WARRANTY Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PAR- TICULAR PURPOSE.
  • Page 5: Instalaciones Típicas

    MODELOS 757PT • 757SN Página 5 VENTILADOR DE CIELO RASO SERIE DECORATIVA LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA INSTALACIONES TÍPICAS PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA O LESIONES PERSONALES, OBSERVE LO SIGUIENTE: 1. Utilice esta unidad solamente de acuerdo con las instruc- ciones del fabricante.
  • Page 6: Instalación De La Cubierta

    MODELOS 757PT • 757SN Página 6 INSTALACIÓN DE LA INSTALACIONES TÍPICAS CUBIERTA (continuación) (continuación) Construcción nueva TECHOS SUSPENDIDOS Cubierta montada con cables. Montaje de tres puntos. INSTALACIÓN DE LA CUBIERTA 3. Coloque la cubierta a un lado e introduzca parcialmente los...
  • Page 7: Conexión Eléctrica

    MODELOS 757PT • 757SN Página 7 CONEXIÓN ELÉCTRICA INSTALACIÓN DE LA CUBIERTA (continuación) DIAGRAMA ELÉCTRICO Construcción existente C O M M . R O J O A Z U L B L A N C O L A M P .
  • Page 8: Uso Y Cuidado

    GARANTIA LIMITADA DE BROAN-NUTONE DE UN AÑO Broan-NuTone le garantiza al consumidor comprador original de sus productos que tales productos estarán libres de defectos en materiales o mano de obra por un período de un año a partir de la fecha de compra original.

This manual is also suitable for:

757sn

Table of Contents