Broan 750 Instructions Manual
Broan 750 Instructions Manual

Broan 750 Instructions Manual

Ventilation fan with light
Hide thumbs Also See for 750:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

VENTILATION FAN
WITH LIGHT
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Circuit Interrupter) - protected branch circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. To reduce the risk of electrical shock, do not use this fan with
any solid-state speed control.
10. Not for use in kitchens.
11. Do not install in a ceiling insulated to a value greater than R-40.
12. This unit must be grounded.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. Please read specification label on product for further information
and requirements.
FOR BEST RESULTS
When installing the Exhaust Fan/Light in a new construction site,
install housing during the rough-in construction of the building. The
blower unit, reflector and grille should be installed after the finished
ceiling is in place.
Hanger Bars
Slots
Tabs
Night Light
Socket
PLANNING DUCTWORK AND WIRING
DUCTWORK
1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside. For
best fan performance, make duct run as short as possible and
use minimum number of elbows.
3. Use optional Broan ducting accessories as needed.
WIRING
Plan to run 120 VAC house wiring (with ground) from power source,
through wall switch, to junction box in housing. For separate control
of fan, light, night light, three wall switches are required and five
conductors are needed between the wall switch box and the fan's
junction box.
IMPORTANT: Use wire suitable for 90
MODEL 750
Page 1
Duct
Collar
Wiring
Knockouts
Housing
Scroll
Power/Blower
Unit
Reflector
Assembly
Acorn Nut
Mounting
Springs (2)
Grille/Lens
Assembly
FIGURE 1
C.
o

Advertisement

Table of Contents
loading

Summary of Contents for Broan 750

  • Page 1 3. Use optional Broan ducting accessories as needed. FOR BEST RESULTS WIRING Plan to run 120 VAC house wiring (with ground) from power source, When installing the Exhaust Fan/Light in a new construction site, through wall switch, to junction box in housing.
  • Page 2: Mounting The Housing

    MODEL 750 Page 2 INSTALLATION IN A NEW CONSTRUCTION SITE PREPARATION 1. Refer to Figure 1. Remove power unit/blower assembly from housing. A. Unplug power unit. B. Remove screw (located next to plug-in receptacle) which holds power/blower unit mounting plate in place. Save screw.
  • Page 3: Completing Installation

    MODEL 750 Page 3 POWER/BLOWER UNIT INSTALLATION 1. Refer to Figure 1. Place power/blower unit into housing so that mounting plate’s tabs insert into slots in housing. 2. Press other end of mounting plate down until it is firmly seated over scroll and plug-in receptacles.
  • Page 4: Service Parts

    Company’s most current written limited warranty for your particular product will control. The most current limited written warranties for the Company’s products can be found at www.broan.com . Broan 926 West State Street, Hartford, WI 53027 www.broan.com 800-637-1453...
  • Page 5: Para Obtener Mejores Resultados

    Para conseguir el mejor rendimiento del ventilador, haga el PARA OBTENER MEJORES RESULTADOS conducto lo más corto posible y utilice los menos codos posibles. 3. Utilice los accesorios opcionales de Broan para conductos si los necesita. Cuando instale la lámpara/ventilador aspirante en una construcción nueva, CABLEADO instale la caja durante la etapa de enterramiento de la instalación eléctrica...
  • Page 6: Montaje De La Caja

    MODELO 750 MODEL 750 Página 6 Page 6 INSTALACION EN UN LUGAR NUEVO DE CONSTRUCCION PREPARACION 1. Refiérase a la Figura 1. Saque el conjunto de la unidad de potencia/soplador de la caja. A. Desenchufe la unidad de potencia. B. Quite el tornillo (localizado junto al receptáculo de clavija) que sostiene la placa de montaje de la unidad de potencia/soplador en su sitio.
  • Page 7 MODELO 750 MODEL 750 Página 7 Page 7 INSTALACION DE LA UNIDAD DE POTENCIA/SOPLADOR 1. Refiérase a la Figura 1. Coloque la unidad de potencia/soplador en la caja para que las lengüetas de la placa de montaje se inserten en las ranuras de la caja.
  • Page 8: Uso Y Cuidado

    Garantía limitada Periodo y exclusiones de la garantía: Broan-NuTone LLC (la “Compañía”) garantiza al consumidor comprador original de su producto (“usted”) que el producto (el “Producto”) estará libre de defectos en materiales o en mano de obra, por un periodo de un (1) año a partir de la fecha de compra original.