LAMP CONTROL
When the actual temperature around the Lamp becomes higher than the preset
value, the Lamp will shut down within 5 minutes automatically.
When the LCD menu displays "Off", restrike of the Lamp MUST be done manually.
When the LCD menu displays "Hot", the actual temperature around the Lamp is
still higher than the preset value and restrike of the Lamp is NOT possible.
When the LCD menu displays the internal temperature with a lowercase letter "c"
(celsius) or "f" (fahrenheit), the Lamp is ON but NOT at 100% full intensity.
When the LCD menu displays the internal temperature with a capital letter "C" or
"F", the Lamp is ON and at 100% FULL intensity.
LAMP CONTROL - Lamp ON or OFF
When ON, manual control of lamp power can be accessed via system menu.
This menu item controls the LAMP ON/OFF software command only. Striking of the
lamp via the system menu can only occur when the LAMP ON/OFF is set to ON, and
the actual temperature around the lamp is lower than the limited value.
LAMP CONTROL - Automatic Lamp ON/OFF
When ON, lamp is automatically powered ON when power is applied to fixture.
LAMP CONTROL - Lamp ON via DMX
When ON, lamp can be powered ON via a DMX controller.
LAMP CONTROL - Lamp OFF via DMX
When ON, lamp can be powered OFF via a DMX controller.
LAMP CONTROL - Lamp ON at Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut OFF to prevent
damage to the lamp and avoid possible internal damage to the fixture head.
This function sets the MIN internal operating temperature of the fixture head before
the lamp will restrike after the lamp has been automatically shut OFF.
LAMP CONTROL - Lamp OFF at Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut OFF to prevent
damage to the lamp and avoid possible internal damage to the fixture head.
This function sets the MAX internal operating temperature of the fixture head when
the lamp will automatically be shut OFF.
W HEN T HE T EM PE RA TU RE A R OUND TH E L AMP IS HI G H ER TH AN T HE PRE S E T
V A LUE C ONT IN UO U S LY F O R U P TO 5 MIN UT ES, T H E L A MP WIL L SH U T OFF
A UTOM ATICA L LY . WH E N T H I S H AP P E NS YOU CAN NOT RE-ST R IKE TH E L A MP
A GA IN A UT OMA T IC A LLY, Y O U MU S T R E- ST RIK E T HE L AMP MAN UA L L Y .
 
w w w . e l a t i o n l i g h t i n g . c o m
         
28
PLATINUM SPOT 35 PRO™ User Manual Version 1