TYPICAL INSTALLATION

INSTALL THE HEADER BRACKET

To prevent possible SERIOUS INJURY or DEATH:
• Header bracket MUST be RIGIDLY fastened to structural
support on header wall or ceiling, otherwise door might not
reverse when required. DO NOT install header bracket over
drywall.
• Concrete anchors MUST be used if mounting header bracket or
2x4 into masonry.
The trolley operator is generally mounted over the center of the door. However, off center mounting may be required due to interfering
structures or location of door stile / top section support. Typically, the operator may be mounted up to 24 inches (60.96 cm) off center
on torsion spring doors. Extension springs require center mounting.
1
Mark the center of the door. Extend the line on to the header
wall and the ceiling.
Level (Optional)
3
Center header bracket over vertical center line and horizontal
line created in step 2. Drill appropriate pilot holes to
accommodate mounting hardware.
Highest Point
of Door Travel
WARNING
WARNING
CAUTION
AVERTISSEMENT
ATTENTION
ADVERTENCIA
PRECAUCIÓN
Header Bracket
Horizontal Line
4" (10 cm)
• NEVER try to loosen, move or adjust door, springs, cables,
pulleys, brackets, or their hardware, ALL of which are under
EXTREME tension.
• ALWAYS call a trained door systems technician if door binds,
sticks, or is out of balance.
2
Determine and mark the highest point of door travel.
Level
4
Secure the header bracket to the header using the appropriate
method.
Hardware
(Not Provided)
9
Header Wall
High Point of
Door Travel
W
AVE
AVE
AD
AD

Hide quick links: