ENTRAPMENT PROTECTION
WARNING
LIFTMASTER MONITORED ENTRAPMENT
CAUTION
PROTECTION (LMEP)
IMPORTANT INFORMATION ABOUT THE LIFTMASTER
MONITORED ENTRAPMENT PROTECTION DEVICES
A LiftMaster Monitored Entrapment Protection (LMEP) device
is required for most wiring types. If a LiftMaster Monitored
Entrapment Protection device is not installed, constant pressure to
close will be required from the control station.
When properly connected and aligned, the photoelectric sensors
will detect an obstruction in the path of its invisible light beam. If
an obstruction breaks the light beam while the door is closing, the
door will stop and typically reverse to the full open position.
The photoelectric sensors must be installed facing each other
across the door, no more than 6" (15 cm) above the fl oor.
AVERTISSEMENT
Each photoelectric sensor has an LED that will glow steady when
the sensor is properly connected and aligned. The LEDs on both
photoelectric sensors will fl icker rapidly when obstructed or
ATTENTION
misaligned.
ADVERTENCIA
PRECAUCIÓN
—Left Side of Garage—
Photoelectric Sensor
Safety Reversing
6" (15 cm) max. above fl oor
Sensor
To prevent possible SERIOUS INJURY or DEATH from a closing
door:
• Be sure power is not connected to the door operator BEFORE
installing the photoelectric sensor.
• The door MUST be in the fully opened or closed position
BEFORE installing the LiftMaster Monitored Entrapment
Protection device.
To prevent SERIOUS INJURY, DEATH, ENTRAPMENT, or
PROPERTY DAMAGE:
• Correctly connect and align the photoelectric sensor.
• Install the photoelectric sensor beam NO HIGHER than
AVERTISSEMENT
6" (15 cm) above the fl oor.
• This is a required safety device for B2, TS, T, and FSTS wiring
types and MUST NOT be disabled. For D1, C2, and E2 wiring
the installation of an entrapment device is recommended.
AVERTISSEMENT
• LiftMaster Monitored Entrapment Protection devices are for
use with LiftMaster Commercial Door Operators ONLY. Use
with ANY other product voids the warranty.
• If an edge sensor is being used on a horizontal slide door,
then place one or more edge sensors on both the leading and
trailing edge.
• If an edge sensor is being used on a vertically moving door,
then place one or more edge sensors on the bottom edge of
the door.
ADVERTENCIA
ADVERTENCIA
Invisible Light Beam
Invisible Light Beam
Protection Area
Protection Area
16
WARNING
WARNING
WARNING
— Right Side of Garage —
Photoelectric Sensor
Safety Reversing
6" (15 cm) max. above fl oor
Sensor

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bmt5011u

Table of Contents