2.1 KNOW THE GENERATOR

Read the Owner's Manual and Safety Rules before operating
this generator.
Compare the generator to Figure 3 to become familiarized with the
locations of various controls and adjustments. Save this manual
for future reference.
1. Run/Stop Switch – Controls the operation of the generator.
2. Fuel Shut Off – Valve between fuel tank and carburetor. Turn
off and run carburetor out of fuel for extended storage.
3. Panel LED's – Provide illumination of the control panel while
the generator is operating.
4. 120/240 Volt AC, 20 Amp Locking Receptacle – Supplies
electrical power for the operation of 120 and/or 240 Volt AC,
20 Amp, single-phase, 60 Hz, electrical lighting, appliance,
tool and motor loads.
5. 120 Volt AC, 20 Amp, GFCI Duplex Receptacle – Supplies
electrical power for the operation of 120 Volt AC, 20 Amp,
single-phase, 60 Hz electrical lighting, appliance, tool and
motor loads. It also provides protection with an Integral
Ground Fault Circuit Interrupter, complete with a press to
"Test" and "Reset" button.
6. Circuit Breakers (AC) – Each push button circuit breaker is
rated at 20 Amps; this protects the generator against electrical
overload.
7. Hourmeter – Provides operating hours for Service Intervals.
8. PowerBar – Indicates the amount of power being used from
the generator; each section is approximately 25%
9. Fuel Tank – Tank holds 4.5 U.S. gallons of fuel.
10. Fuel Gauge – Shows fuel level in tank.
11. Handles – Pivot and retract for storage. Press the spring-
loaded button to move handles.
12. Oil Fill – Check oil level and add oil here.
13. Grounding Lug – Ground the generator to an approved earth
ground here. See "Grounding the Generator" for details.
14. Muffler – Includes the spark arrestor and quiets the engine.
15. Spark Plug – Ignites Air/Fuel Mixture (Side panel must be
removed).
16. Engine Oil Filter – Filters engine oil; see Section 3.1 for the
proper service intervals.
17. Choke – Used when starting a cold engine.
18. Air Cleaner – Filters intake air as it is drawn into the engine.
19. Oil Drain – Drain valve to remove used oil from the engine
crankcase.
20. Recoil Starter – Use to start engine manually.
Figure 3 – Generator Locations and Controls