Packaging List; Appliance Specifications; Unpacking The Appliance; Burn-In Period - Lennox Elite CVF - NG Installation And Operation Instructions Manual

Catalytic vent-free fireplaces
Table of Contents

Advertisement

PACKAGING LIST

Quantity
Description
1
Firebox and Burner Assembly
1
Installation and Operation Instructions
1
Decorative Glass Facia
4
Decorative Spring-Loaded Corner Posts
1
Screw and Wall Plug Pack
1
Rubber Grommet
1
Fitting Template

APPLIANCE SPECIFICATIONS

Gas Type
Max.
Gas Inlet Pressure
Min.
Regulator Pressure Setting
Max Energy Input
Minimum Energy Input
Pilot Energy Input
Main burner flow restrictor
1.16mm (0.046")
(burner orifice)
Oxypilot
Gas Inlet Connection
Ignition
Double Piezo spark
Spark Gap
Please see Data Plate affixed to appliance for current data. This appliance is for use
only with the gas type, and at the pressure stated on the appliance Data Plate.
Table 1

UNPACKING THE APPLIANCE

Remove the outer packaging, remove any instructions or fixing kits .
Read ALL these instructions before continuing to unpack or install this
appliance .
Remove the remaining components from the packaging .
Check that the components supplied with the packaging list, shown above .
Please dispose of all the packaging materials at your local recycling center .
Natural Gas
Propane/LPG
10.5" w.c.
13" w.c.
6" w.c.
11" w.c.
5" w.c.
10" w.c.
6,825 BTU/hour
5,800 BTU/hour
3,412 BTU/hour
3,412 BTU/hour
560 BTU/hour
560 BTU/hour
0.65mm (0.026")
SIT/Bray 9082
SIT/Bray 9284
3/8" NPT
3/8" NPT
Double Piezo spark
1/8" - 3/16"
1/8" - 3/16"

BURN-IN PERIOD

On initial light up of a new appliance, the 'newness' will burn off within
the first few hours of operation . During this period some smoke may be
emitted from outlet grill, this should be no cause for concern . Accord-
ingly, the room should be well ventilated with all windows and doors
open during this period .
Depending on your use, the burn-in period may take a few hours or a few
days . Also if you have a sensitive sense of smell you may notice slight
odors during operating after the burn-in period is over .
KEEP YOUR HOUSE WELL VENTILATED DURING THE BURN-IN PERIOD.
THE ODOR AND HAZE EMITTED DURING THE BURN-IN PERIOD CAN BE
QUITE NOTICEABLE AND MAY SET OFF A SMOKE DETECTOR. MAKE
SURE SMOKE DETECTORS ARE NOT TOO CLOSE TO THE FIREBOX
(CHECK WITH YOUR LOCAL CODE FOR ALLOWABLE DISTANCES).
CODES
Adhere to all local codes or in their absence the latest edition of The
National Fuel Gas Code ANSI Z223 .1 or NFPA 54 which can be obtained
from The American National Standards Institute, Inc . (1430 Broadway,
New York, NY, 10018) or National Fire Protection Association, Inc . (Bat-
terymarch Park, Quincy, MA, 02269) .
Seller of unvented propane or natural gas fired supplemental room
heaters shall provide to each purchaser a copy of 527 CMR 30 upon
sale of the unit .
This Lennox Hearth Products Unvented Gas Room Heater is certified by
OMNI-Test Laboratories, Inc to ANSI Z21 .11 .2 standard .
Massachusetts Requirements
These fireplaces are approved for installation in the US state of Mas-
sachusetts if the following additional requirements are met:
• Unvented Room Heaters shall be installed in accordance with 527
CMR and 248 CMR:
• Installation and repair must be done by a plumber or gas fitter licensed
in the Commonwealth of Massachusetts
• The flexible gas line connector used shall not exceed 36 inches (92
centimeters) in length .
• The individual manual shut-off must be a T-handle type valve .
• Vent-Free appliances may NOT be installed in bedrooms or bathrooms .
• A working smoke detector must be installed in the area where vent-
free appliances are installed .
Seller of unvented propane or natural gas-fired supplemental room heaters
shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit .
New York:
These fireplaces are approved for installation in the US state of New York,
but not in New York City .
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Elite cvf - lp

Table of Contents