Report No. 116-F-15-5
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by a
qualifi ed installer, service agency or the gas sup-
plier
.

INSTALLATION INSTRUCTIONS

MANUAL
B-VENT GAS FIREPLACE HEATER INSERT
Elite™ Series, Model: EBVI25 & EBVI30
Suitable for installation into masonry or factory built fi replaces.
RETAIN THIS MANUAL FOR FUTURE REFERENCE
P/N 775,154M B, 7/2004
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE
POUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE
OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser
d'essence ni d'autre vapeurs ou liquides infl ammables
dans le voisinage de cet appareil ou de tout autre
appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez une
odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones se trouvant dans le batiment où vous
vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service dos incendies.
L'installation et service doit être exécuté par un qualifi é
installeur, agence de service ou le fournisseur de gaz.

Advertisement

Table of Contents
loading

Summary of Contents for Lennox EVB125

  • Page 1: Installation Instructions

    INSTALLATION INSTRUCTIONS MANUAL B-VENT GAS FIREPLACE HEATER INSERT Elite™ Series, Model: EBVI25 & EBVI30 Suitable for installation into masonry or factory built fi replaces. RETAIN THIS MANUAL FOR FUTURE REFERENCE Report No. 116-F-15-5 P/N 775,154M B, 7/2004 WARNING: IF THE INFORMATION IN THIS MANUAL AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LES INSTRUCTIONS DONNÉ...
  • Page 2: Table Of Contents

    fi red heater. It In Canada, the current CSA C22-1 Canadian is our goal at Lennox Hearth Products to provide you, our valued customer, with an appli- Electrical Code - latest edition.
  • Page 3: General Information

    This appliance uses a millivolt type control Manifold Gas Supply Pressure (all models) DO NOT USE THIS APPLIANCE IF ANY PART system consisting of a gas control valve with HAS BEEN UNDER WATER. IMMEDIATELY Fuel # High regulator (control to adjust for fl ame appear- CALL A QUALIFIED, PROFESSIONAL ance and heat output), a standing pilot burner Natural...
  • Page 4: Questions/Building Offi Cials

    6. Maximum amount of gas pipe without a QUESTIONS TO ASK LOCAL BUILDING FIREPLACE REQUIREMENTS OFFICIAL pressure test - type of test required? 7. Are below grade penetrations of the gas IMPORTANT: When installing this appliance This appliance must be installed per into a factory built fi...
  • Page 5: Specifi Cations

    * The Steady State Effi ciency numbers based on maximum vent confi guration. 1 15/16” (49 mm) Note: Due to Lennox' ongoing commitment to quality, all specifi cations, ratings and dimensions are subject to change without notice. The total glass viewing area equals approx. 270 1/2 Sq. In...
  • Page 6 ** The total glass viewing area equals approx. 290 Sq. In. 20 7/8” (530 mm) **23 7/16” (595 mm) *** Due to Lennox' ongoing commitment to quality, all specifi cations, ratings 1 13/16” (46 mm) and dimensions are subject to change without notice.
  • Page 7: Clearance To Combustibles

    MINIMUM CLEARANCES TO COMBUSTIBLES MODELS: EBVI25 & EBVI30 Clearances to Inches (millimeters) Combustibles These appliances can be installed in most residential fi replace EBVI25 EBVI30 Min./Max. confi gurations. If installed close to an adjacent wall, ensure that Side Wall 8” (203 mm) 8”...
  • Page 8: Step 1 Preparation

    MINIMUM FIREPLACE DIMENSIONS The proper gas line diameter must be used Refer to Figures 7 & 8 for Minimum Fire- to run from the supply regulator (at the gas place Clearance Dimensions. See pages 5 company meter) to the appliance. Never use &...
  • Page 9: Step 3 Unpack The Insert

    STEP 6: REMOVE PACKAGED MATERIALS CAUTION: THE FIREPLACE IN WHICH 1) Open the 2 latches below the glass door FROM INSIDE FIREBOX AND SET ASIDE ( as shown in Figures 9 & 10. THIS GAS INSERT IS TO BE INSTALLED set, bag of embers, bag of vermiculite, MUST BE THOROUGHLY CLEANED IF IT propane conversion kit.
  • Page 10 (see Figure 14). Note: Mill-pac, high temperature silicone and/or screws may also be used to secure the liner Lennox Hearth Products - 4" B-Vent Kits to the collar (hose clamp must also be used). Ensure that the draft hood assembly is level with the insert top for attachment.
  • Page 11 Vent Before installing liner, Masonry Fireplace Installation Diagram ensure that the damper plate is open and Liner Vertical secure to prevent the Vent Kits, HO906 (25') Term. Cap damper plate from fall- Flex & H0907 (35') includes: Collar ing down and crushing 1 ea.
  • Page 12: Step 9 Connect Gas Line

    Step 9. CONNECTING GAS LINE Factory Built Fireplace Installation Diagram Note: Final gas connection should be made after unit is in place to avoid Liner Vertical damage to line when pushing the unit into position. Vent Kits, HO906 (25') Term. Cap &...
  • Page 13: Step 11 Install Log Set

    Step 11. INSTALLING LOGS, VERMICULITE AND EMBERS The packaged log set, vermiculite and embers are located within the fi rebox of the insert Rear Log Top Left Log Front Center Log Top Right Log Center Log Front Left Log Figure 21 Front Right Log 2.
  • Page 14: Step 13 Perform Leak Test

    4. Place the Front Left Log onto the 2 corresponding locating pins as shown in Figure 25. Front Left Log Figure 25 Figure 28 Top Right Log 8. Place the glowing embers on the burner as shown in Figure 29. 5.
  • Page 15: Step 12 Reinstall Front Glass Door

    VERIFY THAT THE GAS LINE HAS BEEN PURGED SIT & Honeywell Burner On/Off Switch and Rheostat Location OF AIR (See Step 10). Millivolt Wiring Diagram If optional surround is installed If original wire as supplied must be replaced, it must be Burner On/Off Step 12.
  • Page 16: Step 17 Perform Spillage Test

    ERLY GROUNDED, 120 VOLT, 60 HZ, If spillage continues, The Technician should setting. Allow unit to operate for approximately 3-PRONG RECEPTACLE ELECTRICAL contact Technical Services at Lennox Hearth 15 minutes. Blower should be off. OUTLET. DO NOT CUT OR REMOVE THE Products.
  • Page 17: Step 19 Adjust Burner

    Step 19. BURNER ADJUSTMENT Burner Adjustment Procedure CAUTION: CARBON WILL BE PRODUCED IF THE AIR SHUTTER IS CLOSED TOO MUCH. Flame Appearance and Sooting AIR SHUTTER ADJUSTMENT SHOULD ANY DAMAGE DUE TO CARBONING RESULT- ONLY BE PERFORMED BY AN AUTHO- ING FROM IMPROPERLY SETTING THE AIR Proper fl...
  • Page 18: Rating Plates

    SAFETY / LISTING LABEL MODEL NO. MODEL NO. EBVI25 EBVI30 MANUFACTURED AT: MANUFACTURED AT: Lynwood, CA Union City, TN FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL FOR USE WITH NATURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE 0-4500 FT/PI ALTITUDE 0-4500 FT/PI (0-1370M)
  • Page 20 Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for code requirements for your area. Printed in U.S.A. © LENNOX HEARTH PRODUCTS 2004 P/N 775,154M REV.