SPARK GAP

The gap between the spark electrode and the pilot should be 1/8" to
3/16" to produce a good spark . There should be no need to adjust this
(DO NOT ATTEMPT TO ADJUST THE GAP) . If under any circumstances
the piezo electric spark fails, the pilot cannot be lit manually .
Adjustment to the
1/8" to 3/16" Spark Gap
pilot is Not allowed
Figure 10
FITTING THE DECORATIVE GLASS FACIA
Remove the glass facia panel from any protective packaging . The glass
facia panel is supported by four M6 screws which protrude from the
front of the outer casing .
Ensure each screw is unscrewed approximately one turn from the fully
screwed in position in order to create a 2 mm gap .
Hang the facia panel onto the outer casing ensuring that the correspond-
ing keyhole shaped holes engage the screw-heads fully .
To fit the decorative spring-loaded corner posts, ensure the main glass
facia is mounted in position . Remove any transit tape and unscrew the
front clamping disc and remove .
Compress the decorative spring-loaded corner posts and position
behind the glass panel, lining up with the appropriate hole . Release the
assembly when in position and secure in place by refitting the front
clamping disc .
Figure 11
Figure 12

BRIEFING THE CUSTOMER

Do not add logs or ornaments such as pine cones,
vermiculite or rock wool. Using these added items
can cause sooting.
All instructions must be left in the possession of the user for safekeep-
ing . If at all possible, show the customer how to light and control the
appliance and how to remove and replace the decorative frame .
After commissioning the appliance, the customer should be instructed
on the safe use of the appliance and the need for regular servicing . Fre-
quency of service depends on usage, but MUST be carried out at least
once annually . Advise that cleaning of the appliance may be achieved
when the appliance is cold using a damp cloth and mild detergent on
most surfaces .
Advise that the appliance will emit a "newness" smell for a time after initial
commissioning and that extra ventilation may be needed during this time .
Advise to user to never place any objects on top of the appliance or
obstruction this area in any way .
A periodic visual check of the pilot flame and the burner flame should
be carried out .