Commissioning, inspection, maintenance

Further details regarding the individual steps

Filling the DHW cylinder
1. Fill the DHW cylinder from the DHW
side.
Note
If the DHW cylinder is pressurised,
re-torque the flange cover with a tor-
que of 40 Nm.
The cylinder cap does not need to be
tightened.
2. Check the fittings on the heating
water and DHW side for leaks and
tighten if required.
Inspection and maintenance
DIN 1988 requires a visual inspection
and (if required) cleaning no later than
two years after the cylinder has been
taken into use and thereafter according
to requirements.
6
3. Check sensor wells for leaks and
retighten, if required.
4. Check the function of the safety
valves according to manufacturer's
instructions.