A.3 Shield Termination Technique - Method A.2 (Daisy Chain)
In rare situations where more braids need to be terminated for a connector than three per ring terminal it is
allowable to daisy chain a maximum of two shields together (see Figure A-4) before coming to the ring
terminal. All other restrictions and instructions for the shield termination technique set forth for
Method A.1
are still applicable.
NOTE
The maximum length of the combined braids should be approximately 4 inches.

Figure A-4 Method A.2 (Daisy Chain) for Shield Termination

A.4 Shield Termination – Method B.1 (Quick Term)
If desired, the drain wire termination (item 3, Figure A-4) and the floating shield termination (item 5,
Figure A-4) can be effectively combined into a "Quick Term". This method eliminates the float in the
cable insulation and moves the placement of the window which was described by the dimensions "Window
Min" and "Window Max" from
NOTE
The original purpose for separating the shield drain termination (item 3, Figure A-4) from
the float termination (item 5, Figure A-4) in
lengths for the drain wires so that the shield drain terminations (item 3, Figure A-4) would
not all "bunch up" in the harness and to eliminate loops in the drain wires. If
is chosen, as described in this section, care must be taken to ensure that all drain shield
terminations can still be inspected. With connectors which require a large number of
shield terminations it may be best to use
terminations (item 3, Figure A-4) a larger area to be dispersed across.
Using this method, the instructions from
1. Step 2 is eliminated
2. Steps 3 and 4 are replaced by the following:
At the end of the shielded cable (item 4,
Max" (Table A-3) length of the jacket to expose the shield. Next trim the shield so that at most
0.35 inches remains extending beyond the insulating jacket. Fold this remaining shield back over
the jacket.
190-01553-00
Rev. G
Method
A.1. This technique is depicted in
Method A.1
Method
Section A.2
(Method A) are followed except that:
Figure
Figure
was to allow for a variety of
A.1. This will allow the drain shield
A-1), strip "Quick Term Min" to "Quick Term
GTR 200 Installation Manual
A-5.
Method B.1
Page A-7