Daikin FTXS35K2V1B Service Manual page 79

Inverter pair wall mounted type k-series
Hide thumbs Also See for FTXS35K2V1B:
Table of Contents

Advertisement

SiBE041213E
Troubleshooting
Check No.11
Refer to P.93
Check the power supply voltage.
Check the indoor unit - outdoor
unit connection wires.
Check the voltage of the
connection wires on the indoor
terminal board between No. 1
and No. 3, and between No. 2
and No. 3.
Check the LED A on the outdoor
unit PCB.
Service Diagnosis
Be sure to turn off the power switch before connecting or disconnecting
Caution
connectors, or parts may be damaged.
Is the
power supply
voltage fluctuation within
±10% from the rated
value?
YES
Is there any wiring error?
NO
Properly insulated?
NO
Is LED A blinking?
YES
Rotate the
outdoor fan by hand.
Does the outdoor fan
rotate smoothly?
YES
Check No.11
Check the power supply
waveform.
Is there any disturbance?
YES
NO
YES
YES
∗ Before you check the LED A, cancel
the standby electricity saving
function by starting fan operation
with the remote controller.
∗ Wait at least for 7 sec. after turning
on the power.
NO
NO
NO
Troubleshooting
Correct the power supply.
Correct the indoor unit -
outdoor unit connection wires.
Replace the connection wires
between the indoor unit and
outdoor unit.
Diagnose the outdoor unit
PCB.
Replace both the fan motor
and the outdoor unit PCB.
Replace the indoor unit PCB.
Locate the cause of the
disturbance of the power
supply waveform, and correct
it.
(R18180)