Alignment
MAX Deviation
Set the transceiver to CH 2 (band center).
Inject a 1 kHz tone at –17 dBm to the MIC jack.
Open the "Adjust
Adjust" window on CE44, then select the
Adjust
Adjust
Adjust
"MAX Deviation
MAX Deviation" parameter.
MAX Deviation
MAX Deviation
MAX Deviation
Press the [ ENTER ] key to enable programming of this
parameter; use the [ ] or [ ] arrow keys so that the
deviation meter reading is ±4.2 kHz (±0.1 kHz) (for 25
kHz steps, Ver. D and AS1), ±4.3 kHz (±0.1 kHz) (for
25 kHz steps, Ver. CS) or ±2.1 kHz (±0.1 kHz) (for
12.5 kHz steps) deviation.
Press the [ ENTER ] key to lock in the new data.
CTCSS Deviation
Set the transceiver to CH 2 (band center).
Open the "Adjust
Adjust" window on CE44, then select the
Adjust
Adjust
Adjust
"CTCSS Deviation
CTCSS Deviation" parameter.
CTCSS Deviation
CTCSS Deviation
CTCSS Deviation
Press the [ ENTER ] key to enable programming of this
parameter; use the [ ] or [ ] arrow keys so that the
deviation meter reading is ±0.8 kHz (±0.1 kHz) (for 25
kHz steps) or ±0.5 kHz (±0.1 kHz) (for 12.5 kHz steps)
deviation.
Press the [ ENTER ] key to lock in the new data.
DCS Deviation
Set the transceiver to CH 3 (high band edge).
Open the "Adjust
Adjust" window on CE44, then select the
Adjust
Adjust
Adjust
"DCS Deviation
DCS Deviation" parameter.
DCS Deviation
DCS Deviation
DCS Deviation
Press the [ ENTER ] key to enable programming of this
parameter; use the [ ] or [ ] arrow keys so that the
deviation meter reading is ±0.8 kHz (±0.1 kHz) (for 25
kHz steps) or ±0.5 kHz (±0.1 kHz) (for 12.5 kHz steps)
deviation.
Press the [ ENTER ] key to lock in the new data.
16
RF Frequency
Set the transceiver to CH 2 (band center).
Open the "Adjust
Adjust" window on CE44, then select the
Adjust
Adjust
Adjust
"RF Frequency
RF Frequency" parameter.
RF Frequency
RF Frequency
RF Frequency
Press the [ ENTER ] key to enable programming of this
parameter; use the [ ] or [ ] arrow keys so that the
frequency counter displays the band center frequency
(±100 Hz) for the version being aligned.
Press the [ ENTER ] key to lock in the new data.
Sensitivity
Set the transceiver to CH 3 (high band edge).
Tune the RF signal generator to the same frequency as
the transceiver's, then set the generator output level to
40 dBµ with ±3.0 kHz deviation @ 1 kHz tone modu-
lation.
Open the "Adjust
Adjust" window on CE44, then select the
Adjust
Adjust
Adjust
"RX Tune
RX Tune" parameter.
RX Tune
RX Tune
RX Tune
Press the [ ENTER ] key to enable programming of this
parameter. Use the [ ] or [ ] arrow keys to tune for
best sensitivity; ultimately, the radio should be aligned
so that the RF signal generator output level is –6 dBµ
EMF (0.25 µV) or less for 12 dB SINAD.
Press the [ ENTER ] key to lock in the new data.