Appliance Operation - Baxi Megao System 15 Installation And Service Manual

Gas fired wall mounted condensing system boiler
Table of Contents

Advertisement

Boiler Primary Circuit
18
17
16
15
14
11
Key
1
Heat Exchanger
2
Burner
3
Ignition Electrode
4
Flame Sensing Electrode
5
Gas Valve
6
Pump
7
Automatic Air Vent
8
Pressure Relief Valve
9
Boiler Drain Point
10
Gas Inlet
11
Boiler Flow
12
Boiler Return
13
Pressure Gauge
14
Automatic By-Pass
15
Water Pressure Sensor
16
Safety Thermostat
17
Temperature Sensor
18
Expansion Vessel
19
Return Temperature Sensor
20
Fan
© Baxi Heating UK Ltd 2015
1
20
3
4
5
10

3.0 Appliance Operation

3.1
1. With a demand for heating or hot water, the pump
circulates water through the primary circuit. If the pressure is
at least 0.5 bar and the ignition sequence will start.
2. When the flow temperature exceeds the setting
temperature, a 3 minute delay occurs before the burner
relights automatically (anti-cycling). The pump continues to
run during this period.
2
3. When the demand is satisfied the burner is extinguished
and the pump continues to run for a period of 3 minutes
19
(Pump Overrun).
IMPORTANT: When the selector switch is in the '0'
7
(Off) position the electrical supply to the boiler is
isolated. The boiler will not operate.
6
3.2
13
1. The frost protection mode is integral to the appliance and
functions when the selector switch (see Section 2.1) is in the
ON position (
9
5° C then the boiler will fire on its minimum setting until a
flow temperature of 30° C is reached. Further protection
8
can be incorporated by using a system frost thermostat.
3.3
1. With the selector switch (see Section 2.1) in the ON
position (
12
minute in every 24 hours to prevent sticking.
Fig. 2
Operating Mode (Fig. 2)
Frost Protection Mode
). If the system temperature falls below
Pump Protection
) the pump will automatically operate for 1
9