Technical Specifications; Technical Data - Baxi EcoBlue Advance Combi 24 User Manual

Gas fired wall mounted condensing combination boiler
Hide thumbs Also See for EcoBlue Advance Combi 24:
Table of Contents

Advertisement

3

Technical Specifications

3
Technical Specifications
3.1

Technical Data

Temperatures
C.H. Flow Temp
(adjustable)
25°C to 80°C
D.H.W. Flow Temp
(adjustable)
40°C to 60°C
dependent upon flow rate
Central Heating Primary Circuit
Pressures
Safety Discharge
Max Operating
Min Operating
Recommended Operating Range
Dimensions & Clearances These must be maintained in the event of
any alteration in the property, e.g. additional cupboards etc.
5mm Min
450mm
10
EcoBlue Advance Combi
DHW Circuit
Pressures
(± 5°C)
Max Operating
max
Min Operating
(± 5°C)
max
Flow Rates
DHW Flow Rate
@ 35
o
C Rise
bar
Min Working
3
DHW Flow Rate
2.5
0.5
1-2
5mm Min
175 mm Min (300mm
Min if using 80/125mm
flueing system)
763mm
150mm* Min
bar
8
0.15
(24)
(28)
(33)
(40)
l/min
l/min l/min l/min
9.8
11.5
13.5 16.4
2
2
2
2
450mm Min
For Servicing
Purposes &
Operating the
Controls
5mm Min In
Operation
*
This is MINIMUM
recommended dimension.
Greater clearance will aid
installation and maintenance.
Electrical Supply
230V~ 50Hz
(Appliance must be connected to an
earthed supply)
Electrical Protection
IPX5D (without integral timer)
IP20 (with integral timer)
External Fuse Rating
3A
NOTE: All data in this section are nominal
values and subject to normal production
tolerances.
345mm
7219716 - 01 (04/15)