Minimum Enclosure Clearances - Napoleon GD36NTR Installation And Operation Instructions Manual

Table of Contents

Advertisement

GD36
REAR EXIT ENCLOSURE
COMBUSTIBLE
9
3
/
" MINIMUM
4
42
1
/
"
4
2"
The fi replace requires a minimum enclosure height of
42 1/4". For temperature requirements, the enclosure space
around and above the fi replace must be left unobstructed.
TOP EXIT ENCLOSURE
COMBUSTIBLE
2" MINIMUM
30"
1
1
/
"
2
63"
2"
The fi replace requires a minimum enclosure height of 63".
For temperature requirements, the enclosure space around
and above the fi replace must be left unobstructed.

MINIMUM ENCLOSURE CLEARANCES

NON-COMBUSTIBLE
BRICK
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
2"
AND STONE.
1"
24" MINIMUM
PLUS RISE*
FIGURE 47
NON-COMBUSTIBLE
BRICK
0" IF
2"
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
1"
57" MINIMUM
PLUS RISE*
FIGURE 48
* See chart on Page 6
BGD36
REAR EXIT ENCLOSURE
COMBUSTIBLE
6" MINIMUM
39"
2"
The fi replace requires a minimum enclosure height of 39".
For temperature requirements, the enclosure space around
and above the fi replace must be left unobstructed.
TOP EXIT ENCLOSURE
COMBUSTIBLE
2" MINIMUM
16"
1
1
/
"
2
3
48
/
"
8
2"
The fi replace requires a minimum enclosure height of
48 3/8". For temperature requirements, the enclosure space
around and above the fi replace must be left unobstructed.
NON-COMBUSTIBLE
BRICK
0" IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
2"
AND STONE.
1"
24" MINIMUM
PLUS RISE*
FIGURE 49
NON-COMBUSTIBLE
BRICK
0" IF
2"
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
1"
42
3
/
" MINIMUM
8
PLUS RISE*
FIGURE 50
W415-0210 / Q / 01.17.08
25