1. Fasten the roof support to the roof using the screws
provided. The roof support is optional. In this case the
venting is to be adequately supported using either
an alternate method suitable to the authority having
jurisdiction or the optional roof support. Figure 34.
2. Stretch the 4" fl ex vent pipe to the required length.
Slip the 4" fl ex vent pipe a minimum of 2" over the inner
pipe of the air terminal connector and secure with 3 #8
screws. Seal using a heavy bead of high temperature
sealant W573-0007 (not supplied). Figure 35.
NOTE: If using pipe clamps to connect vent
components, 3 screws must also be used to ensure the connection cannot slip off.
3. Repeat using the 7" fl ex vent pipe, using a heavy bead of high temperature sealant
W573-0002 (not supplied). Figure 35.
4. Thread the air terminal connector / vent pipe assembly down through the roof. The air
terminal must be located vertically and plumb. Attach the air terminal connector to the roof support, ensuring that the top
of the air terminal is 16" above the highest point that it penetrates the roof. Figure 34. DO NOT CLAMP THE FLEX VENT
PIPE.
5. Remove nails from the shingles, above and to the sides of the chimney. Place the fl ashing over the air terminal connector
leaving a min. 3/4" of the air terminal connector showing above the top of the fl ashing. Slide the fl ashing underneath the sides
and upper edge of the shingles. Ensure that the air terminal connector is properly
centred within the fl ashing, giving a 3/4" margin all around. Fasten to the roof. Do
not nail through the lower portion of the fl ashing. Make weather-tight by sealing
with caulking. Where possible, cover the sides and top edges of the fl ashing with
roofi ng material. Figure 36.
6. Aligning the seams of the terminal and air terminal connector, place the terminal
over the air terminal connector making sure the vent pipe goes into the hole in the
terminal. Secure with the three screws provided. Figure 36.
7. Apply a heavy bead of weatherproof caulking 2" above the fl ashing. Note:
Maintain a minimum 2" space between the air inlet base and the storm collar. Install
the storm collar around the air terminal and slide down to the caulking. Tighten to
ensure that a weather-tight seal between the air terminal and the collar is achieved.
Figure 36.
8. If more vent pipe needs to be used to reach the fi replace, couple them together
as illustrated. The vent system must be supported approximately every 3 feet for
both vertical and horizontal runs. Use noncombustible strapping to maintain the
minimum 1" clearance to combustibles. Figure 33.
1. Install the 4" fl ex vent pipe to the fi replace. Secure with 3 screws and fl at washers. Seal
the joint and screw holes using the high temperature sealant W573-0007 (not supplied).
2. Install the 7" fl ex vent pipe to the fi replace. Attach and seal the joints using the high
temperature sealant W573-0002 (not supplied).

USING RIGID VENT COMPONENTS

The vent system must be supported approximately every 3
feet for both vertical and horizontal runs. Use Wolf Steel vent
spacers W615-0033 every 3 feet on either side of each elbow
to maintain the minimum 1¼" clearance between the 7" rigid
vent pipe and 4" rigid vent pipes. Use Napoleon® support ring
assembly W010-0370 or equivalent noncombustible strapping
to maintain the minimum clearance to combustibles for both
vertical and horizontal runs.
W415-0210 / Q / 01.17.08
VERTICAL AIR TERMINAL INSTALLATION

FIREPLACE VENT CONNECTION

FIGURE 34
ROOF SUPPORT
2"
#10x2"
SCREWS
CAULKING
7"RIGID
VENT
PIPE
INNER
PIPE
FIGURE 35
AIR
TERMINAL
CONNECTOR
HIGH
TEMPERATURE
SEALANT
4" FLEX VENT
PIPE
7" FLEX VENT
PIPE
FIGURE 36
AIR INLET
BASE
CAULKING
STORM
COLLAR
WEATHER
SEALANT
FLASHING
#8 X 1/2"
SELF
DRILLING
SCREWS
2" OVERLAP
HI-TEMP SEALANT
FIGURE 37
1"OVERLAP
HI-TEMP
SEALANT
4"RIGID
VENT
PIPE
#8x1/2"
SELF DRILLING
SCREWS
FIGURE 38

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gd36ptrBgd36ntrBgd36ptr

Table of Contents