1

General Information

The Lochinvar SSS series indirect water heater (FIG. 1-1) is
designed to generate domestic hot water in conjunction with
a hot water boiler using forced boiler water circulation. This
indirect water heater consists of a 444 Stainless Steel tank in
which a smooth 304 stainless steel coil is located. Boiler water
is pumped through the coil and heats the water in the tank.
This tank is not intended for use in pool heating applications
or for heating any fluid other than water. It is also not
intended for use in gravity hot water heating systems.
Operating Restrictions:
Maximum Allowable Tank Working Pressure - 150 psi
Design Hydrostatically Tested to 300 psi
Maximum Domestic Hot Water Temperature - 190°F
Maximum Boiler Water Temperature - 210°F
Figure 1-1 Lochinvar SSS Series Indirect Water Heater
4
Installation & Operation Manual
Table 1A
Component Materials
Component
Tank
Coil
Insulation (Top/Bottom)
Insulation Sides
Jacket
Hand Hole Cover Gasket
Material
444 Stainless Steel
304 Stainless Steel
EPS Foam
EPS Foam
Polypropylene
Silicone "O" Ring