Auto Power-Off function

The DelayLab has an Auto Power-Off function that
automatically turns off the power when four hours have
elapsed since the most recent user input.
If the auto power-off function is activated, power will not be
restored even if a switch or pedal is used. Reinsert the cable
into the INPUT (L/MONO) jack to turn on the power.
Even if an there hasn't been any user input, the Auto
Power-Off function will not engage if there is audio
input present at the input jack.
Batteries are consumed even if the auto power-off
function is activated. To avoid consumption of the
batteries, disconnect the cable from the INPUT (L/
MONO) jack and turn off the power.
The Auto Power-Off function is enabled as the factory
default.
TIP:
The setting to enable or disable the auto power-off
function is saved even when the power is turned off.
Enabling the auto power-off function
Press and hold the CATEGORY button and TAP/BANK UP
switch and connect a cable to the INPUT (L/MONO) jack.
Disabling the auto power-off function
Press and hold the FINE button and TAP/BANK UP switch
and connect a cable to the INPUT (L/MONO) jack.

Operating procedure

Using delay effects

1.
Select the effect type with the Type Selector knob.
2.
Select the category with the CATEGORY button.
3.
If necessary, adjust the Edit knobs to reach your
preferred sound.

Saving edited effects

You can save (write) your preferred sounds.
If you switch to a different program or turn off the
power before saving, the changes you've made will be
discarded, and the settings will revert to their original
state.
1.
Press the WRITE button. The save destination of the
program blinks on the display.
2.
Select the save destination bank with the TAP/BANK UP
switch and select the save destination with the Channel
switches A–C.
3.
Press the WRITE button again to start the save function.
After the save function is complete and "CP" appears
on the display, the program number appears. To cancel,
press the CANCEL button.