Clearance Dimensions (Proximity To Cabinets); Clearance Dimensions (Wood/Composite Overlay) - Viking 7 Series Installation Manual

Professional freestanding ranges
Hide thumbs Also See for 7 Series:
Table of Contents

Advertisement

Clearance Dimensions
• This range may be installed directly
• Wall cabinets above the range must be a
adjacent to existing 36" (91.4 cm) high
base cabinets.
IMPORTANT: The side panel MUST be
3/8" (.95 cm) above the adjacent base
cabinet countertop. This can be
accomplished by raising the unit using
the adjustment spindles on the legs.
• The range CANNOT be installed
directly adjacent to sidewalls, tall
cabinets, tall appliances, or other
side vertical surfaces above
36" (91.4 cm) high. There must be
a minimum of 12" (30.5 cm) side
clearance from the range to such
combustible surfaces above the
36" (91.4 cm) counter height.
• Within the 12" (30.5 cm) side
clearance to combustible vertical
surfaces above 36" (91.4 cm), the
3 6
3 6
. 4
. 4
maximum wall cabinet depth
9 1
9 1
(
must be 13" (33.0 cm) and wall
cabinets within this 12" (30.5 cm)
side clearance must be
18" (45.7 cm) above the
36" (91.4 cm) high countertop.
CAUTION
BURN HAZARD
To avoid risk of personal injury;
Note: Minimum clearance for back wall is 3/4"
the use of cabinets for storage
(1.9 cm) with backguard or high-shelf.
above the appliance may result
in a potential burn hazard. Combustible
Note: If a range hood is installed, wall cabinets above
items may ignite, metallic items may
the range have a different minimum clearance height.
become hot and cause burns. If a cabinet
storage is to be provided the risk can be
Note: Clearances from non-combustible materials are
reduced by installing a rangehood that
not part of the ANSI Z21.1 scope and not certified by
projects horizontally a minimum
CSA. Clearances to non-combustible materials must be
5" (12.7 cm) beyond the bottom of cabinets.
approved by the authority having jurisdiction.
10
(Proximity to Cabinets)
minimum of 58" (147.3 cm) above the
range cooking surface for the full width
of the range. This minimum height
requirement does not apply if a range
hood is installed over the cooking surface.
.
.
a x
a x
" m
" m
)
)
1 3
1 3
c m
c m
. 0
. 0
3 3
3 3
(
i n .
i n .
" m
" m
)
)
5 8
5 8
c m
c m
7 . 3
7 . 3
( 1 4
( 1 4
1 2
1 2
" m
" m
( 3 0
( 3 0
i n .
i n .
. 5
. 5
c m
c m
)
)
i n .
i n .
" m
" m
)
)
"
"
1 8
1 8
c m
c m
)
)
c m
c m
. 7
. 7
( 4 5
( 4 5
"
"
3 / 8
3 / 8
)
)
c m
c m
9 5
9 5
( 0 .
( 0 .
A
Range
"A"
Width
Dimension
36"
36" (91.4 cm)
48"
48" (121.9 cm)
Clearance Dimensions
W o
W o
The bottom of a standard hood should be
30" (76.2 cm) min. to 36" (91.4 cm) max.
above the countertop. This would
typically result in the bottom of the hood
being 66" (167.6 cm) to 72" (182.9 cm)
above the floor. Refer to the range hood
installation instructions for additional
information. These dimensions provide for
6 6
6 6
" m
" m
safe and efficient operation of the hood.
( 1 6
( 1 6
i n .
i n .
7 . 6
7 . 6
c m
c m
t o t o
7 2
7 2
" m
" m
( 1 8
( 1 8
a x
a x
2 . 9
2 . 9
c m
c m
W o
W o
o d
o d
/ C o
/ C o
m p
m p
O v
O v
o s i
o s i
e r l
e r l
t e
t e
a y
a y
"
"
3 0
3 0
)
)
c m
c m
3 0
3 0
6 6
6 6
. 2
. 2
" m
" m
" m
" m
( 7 6
( 7 6
( 7 6
( 7 6
( 1 6
( 1 6
i n .
i n .
i n .
i n .
7 . 6
7 . 6
. 2
. 2
c m
c m
c m
c m
t o t o
)
)
3 6
3 6
t o t o
)
)
7 2
7 2
" m
" m
" m
" m
( 9 1
( 9 1
( 1 8
( 1 8
6 " 6 "
a x
a x
a x
a x
m )
m )
. 4
. 4
.
.
2 . 9
2 . 9
.
.
. 2 c
. 2 c
c m
c m
c m
c m
( 1 5
( 1 5
)
)
)
)
Island Installation
11
(Wood/Composite Overlay)
o d
o d
/ C o
/ C o
m p
m p
O v
O v
o s i
o s i
e r l
e r l
t e
t e
a y
a y
"
"
2 4
2 4
)
)
c m
c m
. 0
. 0
( 6 1
( 6 1
o r o r
"
"
2 7
2 7
)
)
c m
c m
. 6
. 6
3 0
3 0
)
)
( 3 8
( 3 8
" m
" m
( 7 6
( 7 6
i n .
i n .
. 2
. 2
.
.
c m
c m
t o t o
)
)
3 6
3 6
)
)
" m
" m
0 " 0 "
( 9 1
( 9 1
m )
m )
a x
a x
. 4
. 4
.
.
0 c
0 c
c m
c m
(
)
)
Wall Installation
Note: Minimum clearance for back wall
is 3/4" (1.9 cm) with backguard or high-
shelf.
Note: This range comes standard with an Island
Trim. There must be a minimum of 6" (15.2 cm)
clearance from rear of range to a combustible
wall or 0" clearance to a non-combustible wall.
Note: Clearances from non-combustible
materials are not part of the ANSI Z21.1 scope
and not certified by CSA. Clearances to non-
combustible materials must be approved by the
authority having jurisdiction.

Hide quick links: