Mitsubishi Electric PUHZ-P200YHA Service Manual page 54

Split-type, heat pump air conditioners
Hide thumbs Also See for PUHZ-P200YHA:
Table of Contents

Advertisement

Outdoor noise filter circuit board
PUHZ-P200YHA
PUHZ-P200YHA3 PUHZ-P250YHA3
GD1
Connect to the earth
CNAC1, CNAC2
AC220/230/240V
(Connect to the
outdoor controller
circuit board (CNAC))
GD2
Connect to the earth
CNDC
(Connect to the
outdoor controller
circuit board
(CNDC))
CNL
Connect to the ACL4
PUHZ-P250YHA
LI1, LI2, LI3, NI
POWER SUPPLY
LI1-LI2/LI-LI3/LI3-LI1 : AC380/400/415V input
LI1-NI/LI2-NI/LI3-NI : AC220/230/240V input
(Connect to the terminal block (TB1))
LO1, LO2, LO3
POWER SUPPLY
LO1-LO2/LO2-LO3/LO3-LO1 : AC380/400/415V OUTPUT
(Connect to the outdoor power circuit board (TB-L1, L2, L3))
54
CNCT
Primary current
(Connect to the
outdoor power
circuit board (CN5))