Roof-Vented Installation; Wall-Vented Installation - LG LMV1314W Installation Instructions Manual

Hide thumbs Also See for LMV1314W:
Table of Contents

Advertisement

ROOF-VENTED INSTALLATION:

1. Remove vent grille by removing two screws on the
vent grille.
2. Turn two mounting rods counter clockwise with flat
blade screwdriver and remove the mounting plate
from the unit. See figure 12.
3. Remove the mount-all from the back plate by
removing two mount-all mounting screws and one
motor mounting screw. See figure 13.
4. Leaving the motor wire connected, lift up, rotate and
reattach the motor so that the exhaust ports face
the top of the cabinet. See figure 14.
5. Use side cutters or tin snips to cut and remove
knockouts from the mount-all. Be careful not to
distort the plate. See figure 15.
6. Reattach the mount-all on the cabinet with three
screws.

WALL-VENTED INSTALLATION:

1. Remove one motor mounting screw and two
mount-all mounting screws. Remove the mount-all
from the oven. See Figure 16.
2. Carefully lift the vent motor out of the microwave
oven.
3. Rotate the vent motor 180˚ so the exhaust ports
face the back of the cabinet. See Figure 17.
4. Place the motor back into microwave oven.
5. Reattach the mount-all. Attach the motor mounting
screw and then two mount-all mount screws. See
Figure 16.
exhaust ports
Use side cutters or tin snips.
Vent motor
motor wire
- 11 -
motor wire
Figure 14
Knockouts
mount-all
Figure 15
motor
Figure 16
mounting screw
exhaust
ports
Figure 17