Sanyo VPC-HD700 Service Manual page 18

Digital movie camera
Hide thumbs Also See for VPC-HD700:
Table of Contents

Advertisement

3-6. The adjustment item which in necessary in part exchange
-6 V (A)
Voltage
Adjust-
ment
COMPL PWB CP-1
COMPL PWB ST-1
COMPL PWB VF-1
COMPL PWB TB-1
COMPL PWB TB-2
ASSY FLEXIBLE
PWB CA1
LENS ASSY
: Be sure to carry out the necessary adjustments after replacing the unit.
: Adjustment is possible from the menu setting screen of the camera and by using the calibration software.
3-7. Adjust Specifications
[CP1 board (Side B)]
CL502
VR502
CCD White
Lens
AWB
Point Defect
Adjust-
Adjust-
Detect
ment
ment
Adjustment
CL302
CL301
CCD Black Point
And White Point
Gyro sensor
Defect Detect
zero offset
Adjustment In
adjustment
Lighted
Note:
1. –6 V (A) voltage adjustment is necessary to repair in the
CP1 board and replace the parts.
1. –6V (A) Voltage Adjustment
Measuring Point
Measuring Equipment
ADJ. Location
ADJ. Value
Adjustment method:
1. Isolate the CP1 circuit board.
2. Use a lead wire to short-circuit CL301 and CL302.
3. Use the accessory AC adapter or a DC power supply to
apply 5 V to the DC jack (JK501).
4. Turn VR502 to adjust the voltage to -6.0 ± 0.1 V.
5. Disconnect the lead wire between CL301 and CL302 which
was connected in step 2.
– 18 –
USB storage
Factory
Language
information
Cord
Setting
registration
Setting
CL502
Digital voltmeter
VR502
± 0.1 V
6.0
Reset
Setting